Specifications of CLC012AJE-TR13/NOPB

Applications
Medical
Voltage - Supply
4.5 V ~ 5.5 V
Package / Case
14-SOIC (3.9mm Width), 14-SOL
Mounting Type
Surface Mount
For Use With
SD012EVK - BOARD EVALUATION CLC012DRIVECABLE02EVK - BOARD EVAL SERDES, CLC001, 012
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Interface
-
Other names
*CLC012AJE-TR13
*CLC012AJE-TR13/NOPB
CLC012AJE-TR13

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CLC012AJE-TR13/NOPB
Manufacturer:
ON
Quantity:
12 000
Evaluation Board
Evaluation boards are available for a nominal charge that
demonstrate the basic operation of the SDI/SDV/SDH de-
vices. The evaluation boards can be ordered through Nation-
al’s Distributors. Supplies are limited, please check for cur-
rent availability.
The SD012EVK evaluation kit for the CLC012, Adaptive
Cable Equalizer for ITU-T G.703 Data Recovery, provides an
operating environment in which the cable equalizer can be
evaluated by system / hardware designers. The evaluation
board has all the needed circuitry and connectors for easy
connection and checkout of the device circuit options as
discussed in the CLC012 datasheet. A schematic, parts list
and pictorial drawing are provided with the board.
From the WWW, the following information may be viewed /
downloaded for most evaluation boards: www.national.com/
appinfo/interface
• Device Datasheet and / or EVK User Manual
15
PCB LAYOUT
The CLC012 requires proper high-speed layout techniques
to obtain best results. A few recommended layout rules to
follow for best results when using the CLC012 Adaptive
Cable Equalizer are:
1. Use a ground plane.
2. Decouple power pins with 0.01 µF capacitors placed
3. Design transmission lines to the inputs and outputs.
4. Route outputs away from inputs.
5. Remove ground plane ≥ 0.025” (0.06mm) from the input
• View a picture of the EVK
• View the EVK Schematic
• View the top assembly drawing and BOM
• View the bottom assembly drawing and BOM
≤ 0.1” (3mm) from the power pins.
and output pads.
www.national.com