W83697HG Nuvoton Technology Corporation of America, W83697HG Datasheet - Page 63

no-image

W83697HG

Manufacturer Part Number
W83697HG
Description
IC LPC SUPER I/O 128-PQFP
Manufacturer
Nuvoton Technology Corporation of America
Datasheet

Specifications of W83697HG

Applications
PC's, PDA's
Interface
LPC
Voltage - Supply
3.3V, 5V
Package / Case
128-XFQFN
Mounting Type
Surface Mount
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
W83697HG
Manufacturer:
Winbond
Quantity:
1 000
Part Number:
W83697HG
Manufacturer:
Nuvoton Technology Corporation of America
Quantity:
10 000
Fan 1 Start-up Duty Cycle Register -- Index 0Ah
Power on default [7:0] = 0000,0001 b
Fan 2 Start-up Duty Cycle Register -- Index 0Bh
Power on default [7:0] = 0000,0001 b
Fan 1 Stop Time Register -- Index 0Ch
Power on default [7:0] = 0011,1100 b
Fan 2 Stop Time Register -- Index 0Dh
Power on default [7:0] = 0011,1100 b
BIT
BIT
BIT
BIT
7-0
7-0
7-0
7-0
START_DC1[7:0]
START_DC2[7:0]
STOP_TIME1[7:0]
STOP_TIME2[7:0]
NAME
NAME
NAME
NAME
Read/Write
READ/WRITE
READ/WRITE
READ/WRITE
READ/WRITE
Read/Write
Read/Write
Read/Write
In Thermal Cruise mode, PWM duty will increase
from 0 to this register value to provide a minimum
duty cycle to turn on the fan. This register should be
written a fan start-up duty cycle.
In Thermal Cruise mode, PWM duty will increase
from 0 to this register value to provide a minimum
duty cycle to turn on the fan. This register should be
written a fan start-up duty cycle.
In Thermal Cruise mode, this register determines the
time of which PWM duty is from stop duty cycle to 0
duty cycle. The unit of this register is 0.1 second. The
default value is 6 seconds.
In Thermal Cruise mode, this register determines the
time of which PWM duty is from stop duty cycle to 0
duty cycle. The unit of this register is 0.1 second. The
default value is 6 seconds.
- 60 -
DESCRIPTION
DESCRIPTION
DESCRIPTION
DESCRIPTION
W83697HF/ HG