R88A-TK07W Omron, R88A-TK07W Datasheet - Page 314

no-image

R88A-TK07W

Manufacturer Part Number
R88A-TK07W
Description
BRACKET
Manufacturer
Omron
Datasheet

Specifications of R88A-TK07W

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R88ATK07W
• Use the following procedure for adjusting predictive control.
Position deviation
4-118
Operation
1.Adjust by normal control.
2.Change the predictive control selection switches.
3.Adjust the predictive control parameters.
Procedure for Adjusting Predictive Control
Functions such as one-parameter tuning or auto-tuning can be used.
Change the predictive control selection switches to use predictive control. After changing the
switch, the power must be turned OFF and back ON.
Adjust the predictive control parameters as required, while checking the response.
Predictive control weighting
ratio (Pn152) is raised.
Time
Chapter 4