Specifications of M29W320DT90N6

Cell Type
NOR
Density
32Mb
Access Time (max)
90ns
Interface Type
Parallel
Boot Type
Top
Address Bus
22/21Bit
Operating Supply Voltage (typ)
3/3.3V
Operating Temp Range
-40C to 85C
Package Type
TSOP
Program/erase Volt (typ)
2.7 to 3.6/12V
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
8/16Bit
Number Of Words
4M/2M
Supply Current
10mA
Mounting
Surface Mount
Pin Count
48
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M29W320DT90N6
Manufacturer:
ST
0
Part Number:
M29W320DT90N6E
Manufacturer:
ST
0
2.10
2.11
2.12
2.13
14/56
Ready/Busy Output (RB)
The Ready/Busy pin is an open-drain output that can be used to identify when the device is
performing a Program or Erase operation. During Program or Erase operations Ready/Busy
is Low, V
Erase Suspend mode.
Note that if V
even if RP is at V
After a Hardware Reset, Bus Read and Bus Write operations cannot begin until Ready/Busy
becomes high-impedance. See
The use of an open-drain output allows the Ready/Busy pins from several memories to be
connected to a single pull-up resistor. A Low will then indicate that one, or more, of the
memories is busy.
Byte/Word Organization Select (BYTE)
The Byte/Word Organization Select pin is used to switch between the x8 and x16 Bus
modes of the memory. When Byte/Word Organization Select is Low, V
x8 mode, when it is High, V
V
V
The Command Interface is disabled when the V
Voltage, V
during power up, power down and power surges. If the Program/Erase Controller is
programming or erasing during this time then the operation aborts and the memory contents
being altered will be invalid.
A 0.1µF capacitor should be connected between the V
Ground pin to decouple the current surges from the power supply. The PCB track widths
must be sufficient to carry the currents required during Program and Erase operations, I
V
V
CC
SS
CC
SS
is the reference for all voltage measurements.
provides the power supply for all operations (Read, Program and Erase).
Ground
Supply Voltage
OL
LKO
. Ready/Busy is high-impedance during Read mode, Auto Select mode and
PP
. This prevents Bus Write operations from accidentally damaging the data
/WP is at V
ID
.
IL
IH
, then the 16 KByte outermost boot block will remain protect
, the memory is in x16 mode.
Table 15
and
Figure
CC
Supply Voltage is less than the Lockout
12.
CC
Supply Voltage pin and the V
IL
, the memory is in
SS
CC3
.