ST7538P013TR STMicroelectronics, ST7538P013TR Datasheet - Page 23

IC TXRX FSK POWER LINE 44TQFP

ST7538P013TR

Manufacturer Part Number
ST7538P013TR
Description
IC TXRX FSK POWER LINE 44TQFP
Manufacturer
STMicroelectronics
Type
Transceiverr
Datasheet

Specifications of ST7538P013TR

Number Of Drivers/receivers
1/1
Voltage - Supply
4.75 V ~ 5.25 V
Mounting Type
Surface Mount
Package / Case
44-TQFP Exposed Pad, 44-eTQFP, 44-HTQFP, 44-VQFP
For Use With
497-5484 - BOARD EVAL ST7538 PWR LINE TXRX
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Protocol
-
Other names
497-4316-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ST7538P013TR
Manufacturer:
NXP
Quantity:
67 000
Part Number:
ST7538P013TR
Manufacturer:
STMicroelectronics
Quantity:
10 000
Part Number:
ST7538P013TR
Quantity:
300
ST7538
4
AUXILIARY ANALOG AND DIGITAL FUNCTIONS
4.1 Band In Use
The Band in Use Block has a Carrier Detection like function but with a different Input Sensibility (77dBµV
Typ.)
and with a different BandPass filter Selectivity (40dB/Dec).
BU line is forced High when a signal in band is detected.
To prevent BU line false transition, BU signal is conditioned to Carrier Detection Internal Signal.
4.2 Time Out
Time Out Function is a protection against a too long data transmission. When Time Out function is enabled
after 1 or 3 second of continuos transmission the transceiver is forced in receiving mode. This function
allows ST7538 to automatically manage the CENELEC Medium Access specification. When a time-out
event occur, TOUT is forced high, and is held high for at least 125 ms. To Unlock the Time Out condition
should be forced High. During the time out period only register access or reception mode are en-
RxTx
abled.
During Reset sequence if
line =”0” & REG_DATA line =”0”, TIMEOUT protection is suddendly en-
RxTx
abled and ST7538 must be configured in data reception after the reset event before starting a new data
transmission.
Time Out time is programmable using Control Register bits 7 and 8 (table 11).
Figure 21. Time-out Timing and Unlock Sequence
RxTx
T
T
T
OUT
OFF
OFFD
TOUT
D03IN1409
4.3 Reset & Watchdog
RSTO Output is a reset generator for the application circuitry. During the ST7538 startup sequence is
forced low. RSTO becomes high after a T
delay from the end of oscillator startup sequence.
RSTO
Inside ST7538 is also embedded a watchdog function. The watchdog function is used to detect the occur-
rence of a software fault of the Host Controller. The watchdog circuitry generates an internal and external
reset (RSTO low for T
time) on expiry of the internal watchdog timer. The watchdog timer reset can
RSTO
be achieved applying a negative pulse on WD pin Fig 22.
Figure 22. Reset and Watchdog Timing
T
T
T
RSTO
WO
RSTO
RSTO
T
WM
T
WD
WD
D03IN1410