PEB24911HV13TR Lantiq, PEB24911HV13TR Datasheet - Page 20
PEB24911HV13TR
Manufacturer Part Number
PEB24911HV13TR
Description
Manufacturer
Lantiq
Datasheet
1.PEB24911HV13TR.pdf
(155 pages)
Specifications of PEB24911HV13TR
Lead Free Status / Rohs Status
Supplier Unconfirmed
- Current page: 20 of 155
- Download datasheet (3Mb)
PEF 24911
Introduction
Data Through Mode
In test mode ’Data Through’ the U-transceiver is forced to enter the ’Transparent’ state
and to issue SL3T (see
Table
12) independently of the wake-up protocol. The DT test
mode is activated by pin DT= set to ’1’. The DT test function can be as well stimulated
by C/I= DT besides the fact that the HW selection impacts all line ports while the SW
selection impacts only the chosen line.
Data Sheet
10
2001-07-16