PEB3086FV14XT Lantiq, PEB3086FV14XT Datasheet - Page 87

PEB3086FV14XT

Manufacturer Part Number
PEB3086FV14XT
Description
Manufacturer
Lantiq
Datasheet

Specifications of PEB3086FV14XT

Control Interface
HDLC
Lead Free Status / Rohs Status
Supplier Unconfirmed
Command
Activation Indication
Loop
Deactivation
Confirmation
Indication
Timing
Receiver not
Synchronous
Activation Request
Illegal Code
Ciolation
Activation Indication AI
Deactivation
Indication
Data Sheet
AR
Abbr.
AIL
DC
Abbr.
TIM
RSY
CVR
DI
Code
1110
1111
Code
0000
0100
1000
1011
1100
1111
Activation Indication Loop
Interim indication during deactivation procedure
Remark
Deactivation Confirmation. Transfers the
transceiver into a deactivated state in which it
can be activated from a terminal (detection of
INFO 0 enabled).
Remark
Receiver is not synchronous
INFO 0 received from terminal. Activation
proceeds.
Illegal code violation received. This function
has to be enabled in TR_CONF0.EN_ICV.
Synchronous receiver, i.e. activation
completed.
Timer (32 ms) expired or INFO 0 received for a
duration of 16 ms after deactivation request
87
Description of Functional Blocks
PEB 3086
2003-01-30
ISAC-SX

Related parts for PEB3086FV14XT