CS5463-IS Cirrus Logic Inc, CS5463-IS Datasheet - Page 41

Other Power Management Single Phase Power/Energy IC

CS5463-IS

Manufacturer Part Number
CS5463-IS
Description
Other Power Management Single Phase Power/Energy IC
Manufacturer
Cirrus Logic Inc
Datasheet

Specifications of CS5463-IS

Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CS5463-ISZ
Manufacturer:
CIRRUS
Quantity:
39
Part Number:
CS5463-ISZ
Manufacturer:
CS
Quantity:
1 045
Part Number:
CS5463-ISZ
Manufacturer:
CIRRUS
Quantity:
20 000
Part Number:
CS5463-ISZ
0
Part Number:
CS5463-ISZR
Manufacturer:
CYPRESS
Quantity:
1 001
Part Number:
CS5463-ISZR
Manufacturer:
CIRRUS
Quantity:
20 000
9. BASIC APPLICATION CIRCUITS
Figure 18
power in a single-phase, 2-wire system while operating
in a single-supply configuration. In this diagram, a shunt
resistor is used to sense the line current and a voltage
divider is used to sense the line voltage. In this type of
shunt-resistor configuration, the common-mode level of
the CS5466 must be referenced to the line side of the
power line. This means that the common-mode poten-
tial of the CS5463 will track the high-voltage levels, as
well as low-voltage levels, with respect to earth ground.
Isolation circuitry is required when an earth-ground-ref-
erenced communication interface is connected.
DS678F2
shows the CS5463 configured to measure
Figure 18. Typical Connection Diagram (Single-phase, 2-wire – Direct Connect to Power Line)
N
R
2
120 VAC
R
1
L
470 nF
R
Note:
Shunt
Indicates common (floating) return.
500 Ω
R
R
I-
I+
R
V-
470 µF
C
C
500
I+
I-
C
C
V+
V-
0.1 µF
Figure 19
tem with complete isolation from the power lines. This
isolation is achieved using three transformers: a general
purpose transformer to supply the on-board DC power;
a high-precision, low-impedance voltage transformer,
with very little roll-off/phase-delay, to measure voltage;
and a current transformer to sense the line current.
Figure 20
many 3-wire residential power systems within the Unit-
ed States, only the two line terminals are available (neu-
tral is not available).
configured to meter a three-wire system with no neutral
available.
C
C
Idiff
Vdiff
0.1 µF
10
15
16
12
11
9
IIN-
VIN+
VIN-
IIN+
VREFIN
VREFOUT
VA+
AGND
14
shows the same single-phase, two-wire sys-
shows a single-phase, 3-wire system. In
13
CS5463
10 Ω
DGND
CPUCLK
PFMON
RESET
XOUT
SCLK
4
VD+
SDO
XIN
SDI
INT
CS
E2
E1
3
5 kΩ
Figure 21
22
21
17
2
1
24
19
7
23
6
5
20
0.1 µF
Mech. Counter
Stepper Motor
4.096 MHz
or
Optional
Source
10 k Ω
Clock
shows the CS5463
Interface
Serial
Data
CS5463
41

Related parts for CS5463-IS