ZSE40F-01-62L SMC Corporation, ZSE40F-01-62L Datasheet
ZSE40F-01-62L
Related parts for ZSE40F-01-62L
ZSE40F-01-62L Summary of contents
Page 1
Set pressure range For positive pressure Nil –0.100 to 1.000 MPa ISE40 For positive pressure ZSE40 For vacuum/compound pressure Set pressure range For vacuum pressure Nil 10.0 to –101.3 kPa –100.0 to 100.0 kPa For compound pressure F Piping specifications ...
Page 2
... Note 3) For ZSE40 (F)/ISE40-- 70 Note 4) For ZSE40F (compound pressure) with “psi” indication, this is 0.03 to 0.04 psi. Note 5) For ZSE40F (compound pressure) with “psi” indication, zero clear is in the range of ±0.01 psi. Example of Internal Circuit and Wiring ZSE40(F) ISE40--22(L)-(M) With analog output 1 kΩ ...
Page 3
Description 3 1/2-digit LED Displays present pressure. Displays each mode. Displays error mode. LED (Green) Displays OUT1 output condition When it is ON, the LED is illuminated. UP button Switching of the mode and set value Calibration Procedures Setting procedure ...
Page 4
ZSE40/ISE40 Series Calibration Procedures Initial Setting 1. Initial condition mode Press the “SET” button for more than 2 seconds until “ displayed. Release it when the display turns to “ ”. Unit mode: When using a product with a unit ...
Page 5
Unit Set It's only subject to ZSE40(F)/ISE40--(L). Unit selection Set the unit by either button or button. : kPa or MPa, : kgf/ bar, : psi, : inHg, : mmHg SET Press “SET” button. OUT1: Selection of ...
Page 6
ZSE40/ISE40 Series Calibration Procedures Auto Preset (In the case of confirming the supply pressure) 1. Auto preset mode Select the Auto preset mode in the initial setting mode and press the “SET” button until “ ” is displayed. ON point ...
Page 7
Dimensions 01 ZSE40(F)/ISE40 MPa OUT1 OUT2 SET Atmospheric release port 7.8 01: R 1/8 T1: NPT 1/8 ZSE40(F)/ISE40-W1 30 MPa OUT1 OUT2 SET Atmospheric release port 7.8 Rc 1/8 12 High Precision, Series Digital Pressure Switch M5 x ...
Page 8
ZSE40/ISE40 Series Dimensions C4 ZSE40 ( F ) /ISE40– 32 MPa OUT1 OUT2 SET Atmospheric release port 7.8 12 One-touch fitting ø4, ø6 ∗ For splash proof use (IP65), insert an air tube into the atmospheric ...