ZSE40-T1-22L SMC Corporation, ZSE40-T1-22L Datasheet

no-image

ZSE40-T1-22L

Manufacturer Part Number
ZSE40-T1-22L
Description
Switch, VACUUM, PNEUMATIC, -101.3 TO 0 KPA, 12-24VDC IN, 80MA NPN (2) AND 1-5VDC OUT
Manufacturer
SMC Corporation
Datasheet

Specifications of ZSE40-T1-22L

Current, Consumption
55 mA or Less
Current, Rating
80 mA (Max.) (Load)
Display Type
3-1⁄2 Digit LED Display
Enclosure Type
IP65
Length, Wire
3 m (Lead)
Output Type
NPN Open Collector
Pressure, Operating
10.0 to -101.3 kPa
Repeatability
± 0.2% F.S. ± 1 Digit or Less
Resistance, Insulation
50 Megohms or More @ 500 VDC (Between Lead Wires and Body)
Size, Port
NPT 1⁄8, M5 x 0.8
Temperature, Ambient
0 to +50 °C
Voltage, Input
12 to 24 VDC
Voltage, Rating
12 to 24 VDC
Voltage, Withstanding
1000 VAC for 1 Minute (Between Lead Wires and Body)
Note 1) Equipped with unit switching function
Note 2) For ZSE40 (F)/ISE40-m -
Note 3) For ZSE40 (F)/ISE40-m -
Note 4) For ZSE40F (compound pressure) with "psi" indication, this is 0.03 to 0.04 psi.
Note 5) For ZSE40F (compound pressure) with "psi" indication, zero clear is in the
ZSE40 (F)
ISE40-m -
With analog output
ZSE40 (F)
ISE40-m -
With auto shift input
Rated pressure range
Operating pressure range/Set pressure range
Withstand pressure
Set pressure
resolution
Applicable fluid
Power supply voltage
Current consumption
Switch output
Repeatability
Hysteresis
Response time (with anti-chattering function)
Output short circuit protection
Display
Display accuracy
Operation indicator light
Analog output
Auto shift input
Environmental
resistance
Temperature characteristics
Port size
Lead wires
Weight
Specifications
Internal circuits and wiring examples
(Types without the unit switching function use SI units (kPa or MPa) only.)
range of ±0.01 psi.
22
30
(Note 1)
Hysteresis mode
Window comparator mode
(L)-(M)
(L)-(M)
(Note 2)
(Note 3)
Enclosure
Ambient temperature range
Ambient humidity range
Withstand voltage
Insulation resistance
Vibration resistance
Impact resistance
k g f/cm X
mmH g
MPa
InH g
kPa
bar
psi
22
62
30
70
1k
6.8k
1.2k
±5% F.S. or less (in rated pressure range)
NPN or PNP 2 outputs
10 to 500Hz at the smaller of amplitude 1.5mm or acceleration 98m/sX(10G) in X, Y, Z directions for 2hrs. each (deenergized)
ZSE40F (Compound pressure)
Output impedance: Approx. 1k
01/T1 types approx. 60g, W1 type approx. 80g, C4/C6/M5 types approx. 92g (each including 0.6m lead wires)
DC (+)
(Brown)
Analog output
(Gray)
OUT1
(Black)
OUT2
(White)
DC (–)
(Blue)
Auto shift input
(Gray)
OUT1
(Black)
OUT2
(White)
DC (–)
(Blue)
DC (+)
(Brown)
Linearity: ±1% F.S. or less
Output voltage: 1 to 5V
–100.0 to 100.0kPa
–100.0 to 100.0kPa
0.02
In a temperature range of 0 to 50°C, ±2% F.S. or less of pressure measured at 25°C
C4: With ø4 One-touch fitting, C6: With ø6 One-touch fitting, M5: M5 female threads
2.5ms or less (with anti-chattering function: 24ms, 192ms and 768ms selections)
Max. applied voltage
Residual voltage
Operating: 0 to 50˚C, Stored: –10 to 60˚C (with no condensation or freezing)
Green LED (OUT1: Lights when ON), Red LED (OUT2: Lights when ON)
980m/s X (100G) in X, Y, Z directions 3 times each (deenergized)
12 to 24VDC
12 to 24VDC
±2% F.S. ±1 digit or less (at ambient temperature of 25 ±3°C)
50M or more (at 500VDC) between lead wires and body
Operating/Stored: 35 to 85% RH (with no condensation)
No-voltage input (reed or solid state), input 5ms or more
3 1/2 digit LED display (sampling cycle: 5 times/sec.)
01: R1/8, M5 x 0.8, T1: NPT1/8, M5 x 0.8, W1: Rc1/8
1000VAC for 1min. between lead wires and body
500kPa
12 to 24VDC ±10%, Ripple (p–p) 10% or less
5 wire oil resistant heavy duty cord (0.15mmX )
0.001
0.001
0.1
0.1
1
Air, Non-corrosive/Non-flammable gas
ZSE40 (F)
ISE40-m -
With analog output
ZSE40 (F)
ISE40-m -
With auto shift input
Max. load current :
ZSE40 (Vacuum pressure)
Output voltage: 1 to 5V ±2.5% F.S. or less (in rated pressure range)
±0.2% F.S. ±1digit or less
Note:
When equipped with auto shift function, the following ranges can be set.
Fixed (3 digits)
10.0 to –101.3kPa
0.0 to –101.3kPa
Set pressure range
62
70
–100.0 to 100.0kPa
55mA or less
10.0 to –101.3kPa
– 0.1 to 1.000MPa
(L)-(M)
(L)-(M)
Variable
IP65
Yes
0.01
:
Output impedance: Approx. 1k
Note4)
Linearity: ±1% F.S. or less
: 30VDC (with NPN output)
80mA
1V or less (with 80mA load current)
High Precision Digital Pressure Switch
1k
6.8k
1.2k
–100.0 to 100.0kPa
–101.3 to 101.3kPa
–1.000 to 1.000MPa
Setting range
ISE40 (Positive pressure)
–0.100 to 1.000MPa
0.000 to 1.000MPa
DC (+)
Analog output
(Gray)
OUT1
(Black)
OUT2
(White)
DC (–)
(Blue)
(Brown)
DC (+)
(Brown)
OUT1
(Black)
OUT2
(White)
DC (–)
(Blue)
Auto shift input
(Gray)
1.5MPa
0.001
0.01
0.01
0.1
12 to 24VDC
12 to 24VDC
1

Related parts for ZSE40-T1-22L

ZSE40-T1-22L Summary of contents

Page 1

... Note 2) For ZSE40 (F)/ISE40 Note 3) For ZSE40 (F)/ISE40 Note 4) For ZSE40F (compound pressure) with "psi" indication, this is 0.03 to 0.04 psi. Note 5) For ZSE40F (compound pressure) with "psi" indication, zero clear is in the range of ±0.01 psi. Internal circuits and wiring examples ZSE40 (F) ...

Page 2

... Set pressure range For positive pressure Nil –0.100 to 1.000MPa ISE40 For Positive Pressure For Vacuum/Compound Pressure ZSE40 Set pressure range For vacuum pressure Nil 10.0 to –101.3kPa For compound pressure F –100.0 to 100.0kPa 01: R1/8 (with M5 female threads) W1: Rc1/8 T1: NPT1/8 (with M5 female threads) Reverse pressure ...

Page 3

... Dimensions 01 ZSE40(F)/ISE40– MPa OUT2 OUT1 SET Atmospheric release port 7.8 01: R 1/8 T1: NPT 1/8 ZSE40(F)/ISE40–W1 30 MPa OUT1 OUT2 SET Atmospheric release port 7.8 12 Rc1 0.8 thread depth 5 2-M3 x 0.5 thread depth 4 ø3.5 For splash proof use (IP65), insert an air tube into the atmospheric release port. ...

Related keywords