ATA6621N-PGPW Atmel, ATA6621N-PGPW Datasheet - Page 6

TXRX LIN 5V REG WATCHDOG 20-QFN

ATA6621N-PGPW

Manufacturer Part Number
ATA6621N-PGPW
Description
TXRX LIN 5V REG WATCHDOG 20-QFN
Manufacturer
Atmel
Type
Transceiverr
Datasheet

Specifications of ATA6621N-PGPW

Number Of Drivers/receivers
1/1
Protocol
LIN
Voltage - Supply
5 V ~ 18 V
Mounting Type
Surface Mount
Package / Case
20-QFN Exposed Pad
Number Of Transmitters
1
Number Of Receivers
1
Power Supply Requirement
Single
Package Type
QFN EP
Operating Temperature Classification
Automotive
Mounting
Surface Mount
Pin Count
20
Operating Temperature (max)
125C
Operating Temperature (min)
-40C
Dual Supply Voltage (typ)
Not RequiredV
Dual Supply Voltage (max)
Not RequiredV
Dual Supply Voltage (min)
Not RequiredV
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3.13
3.14
3.15
Figure 3-1.
3.15.1
3.15.2
6
MODE Input Pin
TM Input Pin
Modes of Operation
Communication: ON
VCC: 5V 2%/50 mA
with undervoltage
monitoring
ATA6621N
Normal Mode
Silent Mode
Normal Mode
Modes of Operation
b
For normal watchdog operation connect pin MODE via an external resistor to GND (see
5-2 on page
dog is switched off.
Pin TM is used in final production measurement at Atmel
nected to GND.
This is the normal transmitting and receiving mode. The voltage regulator is in normal mode and
can source 50 mA. The undervoltage detection is activated. The watchdog needs a trigger signal
from PTRIG or NTRIG to avoid resets at NRES.
A falling edge at EN while TXD is high switches the IC into Silent mode. The TXD signal has to
be logic high during the Mode Select window
independent outputs can be used, or two outputs from the same microcontroller port; in the sec-
ond case, the mode change is only one command. In Silent mode, the transmission path is
disabled. Supply current from V
d
EN = 1
TXD = 1
TXD = 0
EN = 0
EN = 1
EN = 0
VCC: 5V/50 mA with undervoltage
Communication: OFF
EN = 1
24). For debugging your software you can connect pin MODE to 5V and the watch-
monitoring
Pre-normal Mode
Go to silent command
Go to sleep command
Unpowered Mode
Local wake-up event
Local wake-up event
b
V
Batt
= 0
a
Bat
is typically I
c + e
(Figure 3-2 on page
Communication: OFF
VSsi
VCC: switched off
= 40 µA with no load at the VCC regulator.
Sleep Mode
b
c + d + e
®
. In the application it is always con-
a: V
b: V
c: Bus wake-up event
d: NRES switches to low
e: Wake-up from wake-up switch
b
VCC: 5V 7%/50 mA
with undervoltage monitoring
Communication: OFF
S
S
> 5V
< 4V
7). For EN and TXD either two
Silent Mode
4887I–AUTO–09/09
Figure

Related parts for ATA6621N-PGPW