VX2110-01T-3CR1 SMC Corporation, VX2110-01T-3CR1 Datasheet - Page 5

no-image

VX2110-01T-3CR1

Manufacturer Part Number
VX2110-01T-3CR1
Description
Process Solenoid Valve, 2 port, direct operated, 1/8 port, NC, 110VAC, conduit
Manufacturer
SMC Corporation
Type
Direct Operatedr
Datasheet

Specifications of VX2110-01T-3CR1

Brand/series
VX Series
Number Of Ports
2
Primary Type
Solenoid Valve
Size, Port
1⁄8" NPTF
Voltage, Coil
110 VAC
Enclosure
Equivalent to IP65
Standard Specifications
∗ Electrical entry: Grommet with surge voltage suppressor (GS) has a rating of IP40.
Solenoid Coil Specifications
Normally Closed (N.C.)
DC Specification
AC Specification (Class B coil, Built-in full-wave rectifier type)
∗ There is no difference in the frequency and the inrush and energized
Note) The value at ambient temperature of 20C and when the rated voltage is
AC Specification
Note) The value at ambient temperature of 20C and when the rated voltage is
2
Valve
specifications
Coil
specifications
apparent power, since a rectifying circuit is used in the AC (Class B coil,
built-in full-wave rectifier type).
applied.
applied.
Model
VX21
VX22
VX23
Model
Model
VX21
VX22
VX23
VX21
VX22
VX23
Frequency (Hz)
Valve construction
Withstand pressure
Body material
Seal material
Enclosure
Environment
Rated voltage
Allowable voltage fluctuation
Allowable
leakage
voltage
Coil insulation type
50
60
50
60
50
60
Common Specifications
Power consumption (W)
Apparent power (VA) ∗
AC (Class B coil, Built-in full-wave rectifier type)
12
10.5
7
9.5
Apparent power (VA)
Inrush
4.5
7
19
16
43
35
62
52
AC (Class B coil/H coil)
DC (Class B coil only)
Energized
Temperature rise (C)
Temperature rise (C)
10
20
17
32
27
8
MPa
45
45
60
55
60
65
Temperature
AC
DC
rise (C)
50
45
65
60
65
60
Note)
Note)
Note)
Normally Open (N.O.)
DC Specification
AC Specification (Class B coil, Built-in full-wave rectifier type)
∗ There is no difference in the frequency and the inrush and energized
Note) The value at ambient temperature of 20C and when the rated voltage is
AC Specification
Note) The value at ambient temperature of 20C and when the rated voltage is
apparent power, since a rectifying circuit is used in the AC (Class B coil,
built-in full-wave rectifier type).
100 VAC, 200 VAC, 110 VAC, 220 VAC, 230 VAC, 240 VAC, 48 VAC
applied.
applied.
Model
VX21
VX22
VX23
Model
Model
VX21
VX22
VX23
VX21
VX22
VX23
Dusttight, Low jetproof (equivalent to IP65)
Location without corrosive or explosive gases
Frequency (Hz)
10% or less of rated voltage
20% or less of rated voltage
Brass (C37), Stainless steel
50
60
50
60
50
60
2% or less of rated voltage
NBR, FKM, EPDM, PTFE
Power consumption (W)
Apparent power (VA) ∗
Direct operated poppet
10% of rated voltage
24 VDC, 12 VDC
Class B, Class H
12
10.5
7
9.5
Apparent power (VA)
4.5
7
Inrush
5.0
22
18
46
38
64
54
Energized
Temperature rise (C)
Temperature rise (C)
11
20
18
32
27
8
Note)
45
45
60
55
60
65
Temperature
rise (C)
55
50
65
60
65
60
Note)
Note)
Note)

Related parts for VX2110-01T-3CR1