VX2110-01T-3CR1 SMC Corporation, VX2110-01T-3CR1 Datasheet - Page 34

no-image

VX2110-01T-3CR1

Manufacturer Part Number
VX2110-01T-3CR1
Description
Process Solenoid Valve, 2 port, direct operated, 1/8 port, NC, 110VAC, conduit
Manufacturer
SMC Corporation
Type
Direct Operatedr
Datasheet

Specifications of VX2110-01T-3CR1

Brand/series
VX Series
Number Of Ports
2
Primary Type
Solenoid Valve
Size, Port
1⁄8" NPTF
Voltage, Coil
110 VAC
Enclosure
Equivalent to IP65
(4) Test method
C
b
P
P
t
Note) Formula of subsonic flow is the elliptic analogous curve.
Flow characteristics are shown in Graph (1) For details, please make use of SMC’s “Energy Saving Program”.
Example)
Obtain the air flow rate for
C
According to formula 1, the maximum flow rate
Pressure ratio
Based on Graph (1), it is going to be 0.7 if it is read by the pressure ratio as 0.8 and the flow ratio to be
Hence, flow rate = Max. flow x flow ratio = 600 x 0.7 = 420 [dm
Attach a test equipment with the test circuit shown in Fig. (1) while maintaining the upstream pressure to a certain level which
does not go below 0.3 MPa. Next, measure the maximum flow to be saturated in the first place, then measure this flow rate at
80%, 60%, 40%, 20% and the upstream and downstream pressure. And then, obtain the sonic conductance
maximum flow rate. Besides that, substitute each data of others for the subsonic flow formula to find
pressure ratio
1
2
= 2 [dm
: Sonic conductance [dm
: Critical pressure ratio [—]
: Upstream pressure [MPa]
: Downstream pressure [MPa]
: Temperature [C]
3
/(s·bar)] and
supply
Air
= ————— =
b
from that average.
0.3 + 0.1
0.4 + 0.1
Filter
b
Pressure control
= 0.3.
P
equipment
1
3
= 0.4 [MPa],
/(s·bar)]
0.8
Fig. (1) Test circuit based on ISO 6358, JIS B 8390
Shut off
valve
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
1
0
0 0.10.20.30.40.50.60.70.80.9 1
Graph (1) Flow characteristics
P
ø
2
d
Pressure ratio (
Solenoid Valve Flow Characteristics
= 0.3 [MPa],
3
=
b =
P
3
Pipe for measuring
600 x 2 x (0.4 + 0.1) x
d
1
1
temperature
0.1
Equipment
Thermometer
10
0.2
C
d
t
,
3
= 20 [C] when a solenoid valve is performed in
0.3
b
pressure in the
upstream side
P
3
3
pressure convertor
Pressure gauge or
measuring
/min (ANR)]
d
2
Pipe for
3
+ 0.1) / (
10
0.4
P
d
Q
2
1
Equipment
for test
3
P
Differential pressure gauge or
differential pressure converter
————— = 600 [dm
d
1
273 + 20
1
downstream side
+ 0.1)
10
pressure in the
293
measuring
d
0.5
Pipe for
2
0.6
Flow control
3
d
valve
2
Flow meter
3
/min (ANR)]
b
b
, then obtain the critical
= 0.3.
C
from this
31

Related parts for VX2110-01T-3CR1