VX2110-01T-3CR1 SMC Corporation, VX2110-01T-3CR1 Datasheet - Page 40

no-image

VX2110-01T-3CR1

Manufacturer Part Number
VX2110-01T-3CR1
Description
Process Solenoid Valve, 2 port, direct operated, 1/8 port, NC, 110VAC, conduit
Manufacturer
SMC Corporation
Type
Direct Operatedr
Datasheet

Specifications of VX2110-01T-3CR1

Brand/series
VX Series
Number Of Ports
2
Primary Type
Solenoid Valve
Size, Port
1⁄8" NPTF
Voltage, Coil
110 VAC
Enclosure
Equivalent to IP65
1. Maximum operating pressure differential
2. Minimum operating pressure differential
3. Maximum system pressure
4. Proof pressure
1. Apparent power (VA)
2. Surge voltage
3. Degree of protection
The maximum pressure differential (the difference between
the inlet and outlet pressure) which is allowed for operation,
with the valve closed or open. When the outlet pressure is 0
MPa, this becomes the maximum operating pressure.
The minimum pressure differential (the difference between the
inlet pressure and outlet pressure) required to keep the main
valve fully opened.
The maximum pressure that can be applied inside the
pipelines (line pressure).
(The pressure differential of the solenoid valve portion must
be less than the maximum operating pressure differential.)
The pressure in which the valve must be withstood without a
drop in performance after holding for one minute under
prescribed pressure and returning to the operating pressure
range. (value under the prescribed conditions)
Volt-ampere is the product of voltage (V) and current (A).
Power consumption (W): For AC , W = V·A·cosθ. For DC, W =
V·A.
(Note) cosθ shows power factor. cosθ = 0.6
A high voltage which is momentarily generated by shutting off
the power in the shut-off area.
A degree defined in the “JIS C 0920: Waterproof test of
electric machinery/appliance and the degree of protection
against the intrusion of solid foreign objects”.
IP65: Dusttight, Low jetproof type
“Low jetproof type” means that no water intrudes inside an
equipment that could hinder from operating normally by
means of applying water for 3 minutes in the prescribed
manner. Take appropriate protection measures, since a
device is not usable in an environment where a droplet of
water is splashed.
Electrical Terminology
Pressure Terminology
Glossary of Terms
1. Material
2. Oil-free treatment
3. Passage symbol
NBR: Nitrile rubber
FKM: Fluoro rubber – Trade names: Viton
EPDM: Ethylene propylene rubber
PTFE: Polytetrafluoroethylene resin – Trade names: Teflon
Polyflon
The degreasing and washing of wetted parts.
In the JIS symbol (
condition (
(
IN), there is a limit to the blocking.
( ) is used to indicate that blocking of reverse pressure is not
possible.
®
, etc.
O
), but actually in the case of reverse pressure
U
Others
) IN and OUT are in a blocked
T
®
, Dai-el
®
>
, etc.
37
®
,

Related parts for VX2110-01T-3CR1