ES-UA-5A BANNER ENGINEERING, ES-UA-5A Datasheet - Page 8

no-image

ES-UA-5A

Manufacturer Part Number
ES-UA-5A
Description
Sensor, E-stop Module, output 6A,
Manufacturer
BANNER ENGINEERING
Type
Safetyr
Datasheets

Specifications of ES-UA-5A

Contact Form
4-NO/1-NC
Dimensions
45mmW×84mmH×118mmD
Enclosure Rating
IP20
Ip Rating
IP20
Mounting Type
DIN Rail
Number Of Outputs
8
Output Type
Relay
Power, Rating
4 W
Primary Type
Controller
Standards
UL, CSA, CE
Voltage, Supply
115/12 to 24 VAC/VDC
Coil Voltage Vdc Nom
24V
Coil Resistance
250ohm
Contact Current Max
6A
Contact Voltage Ac Nom
24V
Contact Voltage Dc Nom
250V
Contact Configuration
SPST-NC
No. Of Poles
1
Relay Mounting
DIN Rail
Lead Free Status / Rohs Status
RoHS Exempt Product
For Use With
Emergency Stop
Automatic Reset Mode
The Safety Module may be configured (via hookup) for automatic reset. If no MSC contacts are monitored, install a
jumper between terminals S32 and S35 (see hookups). The Safety Module will reset (and its outputs energize) as
soon as the switch returns to its armed (closed-contact) position.
Automatic reset is useful for some automated processes. However, if automatic reset is used, it is necessary to
provide a means of preventing resumption of hazardous machine motion, until an alternate reset procedure
is performed. The alternate procedure must include a reset/restart switch, located outside the area of dangerous
motion, which is positioned so that any area of dangerous motion may be observed by the switch operator during
the reset procedure. See Warning.
Connection to the Machine to be Controlled
The machine hookup diagrams show a generic connection of the Safety Module's redundant output circuits to the
master stop control elements (MSCs). An MSC is defined as an electrically powered device, external to the Safety
Module, which stops the machinery being controlled by immediately removing electrical power to the machine and
(when necessary) by applying braking to dangerous motion. This stopping action is accomplished by removing
power to the actuator of either MSC.
External Device Monitoring
To satisfy the requirements of Control Reliability (OSHA and ANSI), Category 3 and 4 of ISO 13849-1 (EN 954-1),
the Machine Primary Control Elements (MPCEs) must each offer a normally closed, forced-guided (mechanically
linked) monitor contact. Connect one normally closed monitor contact from each Machine Primary Control Element
as shown in the appropriate hookup drawing.
In operation, if one of the switching contacts of either MPCE fails in the energized condition, the associated monitor
contact will remain open. Therefore, it will not be possible to reset the Primary Safety Device. If no MPCE-monitor
contacts are monitored, it is the user's responsibility to ensure that any single failure will not result in a haz-
ardous condition and will prevent a successive machine cycle.
8
U.S. and international standards require that a reset routine be performed after clearing the cause of a stop condition
(e.g., arming an E-stop button, closing an interlocked guard, etc.). Allowing the machine to restart without ac-
tuating the normal start command/device can create an unsafe condition which could result in serious injury
or death.
WARNING . . . Reset Routine Required
Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com
Tel: 763.544.3164
ES-UA-5A and ES-VA-5A E-Stop Safety Modules
P/N 122365 rev. C