ES-UA-5A BANNER ENGINEERING, ES-UA-5A Datasheet - Page 2

no-image

ES-UA-5A

Manufacturer Part Number
ES-UA-5A
Description
Sensor, E-stop Module, output 6A,
Manufacturer
BANNER ENGINEERING
Type
Safetyr
Datasheets

Specifications of ES-UA-5A

Contact Form
4-NO/1-NC
Dimensions
45mmW×84mmH×118mmD
Enclosure Rating
IP20
Ip Rating
IP20
Mounting Type
DIN Rail
Number Of Outputs
8
Output Type
Relay
Power, Rating
4 W
Primary Type
Controller
Standards
UL, CSA, CE
Voltage, Supply
115/12 to 24 VAC/VDC
Coil Voltage Vdc Nom
24V
Coil Resistance
250ohm
Contact Current Max
6A
Contact Voltage Ac Nom
24V
Contact Voltage Dc Nom
250V
Contact Configuration
SPST-NC
No. Of Poles
1
Relay Mounting
DIN Rail
Lead Free Status / Rohs Status
RoHS Exempt Product
For Use With
Emergency Stop
ES-UA-5A and ES-VA-5A E-Stop Safety Modules
Important ... read this before proceeding!
The user is responsible for satisfying all local, state, and national laws, rules, codes, and regulations relating
to the use of this product and its application. Banner Engineering Corp. has made every effort to provide complete
application, installation, operation, and maintenance instructions. Please direct any questions regarding the use or
installation of this product to the factory applications department at the telephone numbers or address shown on
back cover.
The user is responsible for making sure that all machine operators, maintenance personnel, electricians, and su-
pervisors are thoroughly familiar with and understand all instructions regarding the installation, maintenance, and
use of this product, and with the machinery it controls. The user and any personnel involved with the installation and
use of this product must be thoroughly familiar with all applicable standards, some of which are listed below. Banner
Engineering Corp. makes no claim regarding a specific recommendation of any organization, the accuracy or effec-
tiveness of any information provided, or the appropriateness of the provided information for a specific application.
Applicable U.S. Standards
ANSI B11 General Safety Requirements
ANSI B11.19 Performance Criteria for Safeguarding
Contact: Safety Director, AMT The Association for Manufacturing Technology, 7901 Westpark Drive, McLean,
VA 22102, Tel.: 703-893-2900
ANSI NFPA79, Electrical Standard for Industrial Machinery
Contact: National Fire Protection Association, 1 Batterymarch Park, P.O. Box 9101, Quincy, MA 02269-9101,
Tel.: 800-344-3555
ANSI/RIA R15.06, Safety Requirements for Industrial Robots and Robot Systems
Contact: Robotic Industries Association, 900 Victors Way, P.O. Box 3724, Ann Arbor, MI 48106, Tel.: 734-994-
6088
Applicable International Standards
ISO 12100-1 (EN292-1), Safety of Machinery – Basic Concepts, General Principles for Design, Part 1: Basic Termi-
nology, Methodology
ISO 12100-2 (EN292-2), Safety of Machinery – Basic Concepts, General Principles for Design, Part 2: Technical
Principals and Specifications
IEC 60204-1, Electrical Equipment of Machines: General Requirements
IEC 61508, Functional Safety of Electrical/Electronic/Programmable Electronic Safety-Related Systems
IEC 62061, Safety of Machinery – Functional Safety of Safety-Related Electrical, Electronic and Programmable
Electronic Control Systems
ISO 13849-1 (EN954-1), Safety of Machinery – Related Parts of Control Systems: Part 1 General Principles for
Design
ISO 13850 (EN418), Emergency Stop Devices
Contact: Global Engineering Documents, 15 Inverness Way East, Englewood, CO 80112-5704, Tel.: 800-854-
7179
2
Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com
P/N 122365 rev. C
Tel: 763.544.3164

Related parts for ES-UA-5A