ES-FA-9AA BANNER ENGINEERING, ES-FA-9AA Datasheet - Page 2

no-image

ES-FA-9AA

Manufacturer Part Number
ES-FA-9AA
Description
Module; Relay; Red LED; 24; UL Listed
Manufacturer
BANNER ENGINEERING
Datasheets

Specifications of ES-FA-9AA

Light Source
Red LED
Coil Voltage Vac Nom
24V
Coil Voltage Vdc Nom
24V
Contact Current Max
6A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
250V
Contact Configuration
3PST-NO
No. Of Poles
3
Lead Free Status / Rohs Status
RoHS Exempt Product
E-Stop Safety Module –

Banner Engineering Corp. has made every effort to provide complete application, installation, operation, and maintenance instructions.
In addition, any questions regarding the use or installation of this Banner Emergency Stop Safety Module should be directed to the
factory applications department at the telephone numbers or address shown on back cover.
The user shall ensure that all machine operators, maintenance personnel, electricians, and supervisors are thoroughly familiar with
and understand all instructions regarding the installation, maintenance, and use of this Emergency Stop Safety Module, and with the
machinery it controls.
The user and any personnel involved with the installation and use of this model Emergency Stop Safety Module must be
thoroughly familiar with all applicable ANSI/NFPA standards. The standards, listed below, directly address the use of emergency
stop systems. Banner Engineering Corp. makes no claim regarding a specific recommendation of any organization, the accuracy or
effectiveness of any information provided, or the appropriateness of the provided information for a specific application.
The user has the responsibility to ensure that all local, state, and national laws, rules, codes, and regulations relating to the use of this
Emergency Stop Safety Module in any particular application are satisfied. Extreme care is urged that all legal requirements have been
met and that all installation and maintenance instructions contained in this manual are followed.
U. S. Standards Applicable to Use of Emergency Stop Safety Modules
European Standards Applicable to Use of Emergency Stop Safety Modules
P/N 60606 rev. B
ANSI B11
NFPA79
ANSI/RIA R15.06 “Safety Requirements for Industrial Robots and Robot Systems”
ISO/TR 12100-1 & -2 (EN292-1 & -2) “Safety of Machinery – Basic Concepts, General Principles for Design
ISO 13849-1 (EN954-1)
IEC/EN60204-1
ISO 13850 (EN418) “Safety of Machinery – Emergency Stop Equipment Functional Aspects, Principles for Design”
Important
Standards for Machine Tools “Safety Requirements for the Construction, Care and Use”
Available from:
“Electrical Standard for Industrial Machinery (1997)”
Available from:
Available from:
...
read this page before proceeding!
Safety Director
AMT – The Association for Manufacturing Technology
7901 Westpark Drive
McLean, VA 22102
Tel.: 703-893-2900
National Fire Protection Association
1 Batterymarch Park, P.O. Box 9101
Quincy, MA 02269-9101
Tel.: 800-344-3555
Robotic Industries Association
900 Victors Way, P.O. Box 3724
Ann Arbor, MI 48106
Tel.: 734-994-6088
Part 1: Basic Terminology, Methodology, and
Part 2: Technical Principals and Specifications”
“Safety of Machines: Safety Related Parts of Control Systems”
“Electrical Equipment of Machines: Part 1: General Requirements”
Also, request a type “C” standard for your specific machinery.
Available from: Global Engineering Documents
ES-FA-9AA
15 Inverness Way East
Englewood, CO 80112-5704
Tel.: 800-854-7179
Banner Engineering Corp.
www.bannerengineering.com • Tel: 763.544.3164
Minneapolis, MN U.S.A.

Related parts for ES-FA-9AA