Description
Module; Relay; Red LED; 24; UL Listed
Manufacturer
BANNER ENGINEERING
Datasheets

Specifications of ES-FA-9AA

Light Source
Red LED
Coil Voltage Vac Nom
24V
Coil Voltage Vdc Nom
24V
Contact Current Max
6A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
250V
Contact Configuration
3PST-NO
No. Of Poles
3
Lead Free Status / Rohs Status
RoHS Exempt Product
Printed in USA
WARNING . . .
OSHA regulations. It is necessary to install point-of-operation guarding devices, such as safety light curtains and/or
hard guards, to protect personnel from hazardous machinery. Failure to install point-of-operation guards on hazardous
machinery can result in a dangerous condition which could lead to serious injury or death.
This Emergency Stop Safety Module is not a point-of-operation guarding device, as defined by
®
• Monitors one dual-channel normally closed emergency stop switch circuit for
• The ES-FA-9AA has three output switching channels for connection to control-
• Auto reset or monitored manual reset
• Design complies with standards UL991, ISO 13850 (EN418), and ISO 13849-1
• For use in functional stop category 0 applications per NFPA 79 and IEC/EN60204-1
• 6 amp safety output contacts
• Plug-in terminal blocks
• 24V ac/dc operation
Emergency Stop Safety Modules
Model ES-FA-9AA (24V ac/dc, 3 N/O)
a contact failure or wiring fault
reliable power interrupt circuits
(EN954-1) (Safety Category 4)
12/05
Features
P/N 60606 rev. B

Related parts for ES-FA-9AA

ES-FA-9AA Summary of contents

Page 1

... Model ES-FA-9AA (24V ac/dc, 3 N/O) • Monitors one dual-channel normally closed emergency stop switch circuit for a contact failure or wiring fault • The ES-FA-9AA has three output switching channels for connection to control- reliable power interrupt circuits • Auto reset or monitored manual reset • ...

Page 2

... ISO 13849-1 (EN954-1) IEC/EN60204-1 ISO 13850 (EN418) “Safety of Machinery – Emergency Stop Equipment Functional Aspects, Principles for Design”  P/N 60606 rev. B ES-FA-9AA read this page before proceeding! Safety Director AMT – The Association for Manufacturing Technology 7901 Westpark Drive McLean, VA 22102 Tel ...

Page 3

... E-stop switch is the first step towards control reliability in an emergency stop circuit. The output of the E-Stop Safety Module ES-FA-9AA consists of three redundant output switching channels, each of which is the series connection of two forced-guided relay contacts that are internally monitored (K1 and K2 in Figure 2). If the Module detects a failure, such as a welded output relay contact, all outputs are disabled and cannot be reset ...

Page 4

... If not, the unit will go into a lockout condition that results in the outputs opening and requiring a reset after the fault has been corrected. 4 P/N 60606 rev. B ES-FA-9AA ! WARNING . . . 1-Channel Input If a 1-channel E-stop ...

Page 5

... Jumper S4 MSC See WARNING Below Machine Master Stop Control Elements MSC1 4 MSC MSC 4 *Arc suppressors (see WARNING) ES-FA-9AA Manual Reset +V dc common 4V ac/ S ES-FA-9AA S11 S4 (No Connection) S1 E-Stop Switch S S1 Machine Master Stop Control Elements 6A max max Machine  4 Control Circuits 6A max ...

Page 6

... S4 MSC See WARNING on page  Machine Master Stop Control Elements MSC1 Machine 4 MSC MSC 4 *Arc suppressors (see WARNING) Manual Reset dc common 4V ac/dc E-Stop Switch A A1 S ES-FA-9AA S11 (No Connection) S4 S1 S S1 Machine Master Stop Control Elements 6A max MSC1 6A max MSC Control Circuits 6A max ...

Page 7

... Module which interfaces to a multitude of machine control configurations. The following guidelines are general in nature. The ES-FA-9AA Module has no delay function. Its output relay contacts open within 25 milliseconds after an E-stop switch contact opens. This classifies these E-Stop Safety Modules as functional “Category 0” E-stop controls, as defined by NFPA 79 (National Fire Protection Association Standard for Industrial Machinery) and IEC/EN60204-1 (European Standard: “ ...

Page 8

... Reset procedure. Automatic Reset Mode The ES-FA-9AA module may be used also with automatic reset MSC-monitor contacts are monitored, a jumper must be installed between terminals S33 and S34 (see Figures 2 and 3). The E-Stop Safety Module will reset (and the outputs energize) as soon as the E- stop switch returns to its closed-contact position ...

Page 9

... Return the E-stop switch to its closed-contact position. Verify that the machine does not restart. 3. Close and then open the Reset switch (if using manual reset mode). Verify that the machine restarts. NOTE: If two or more E-stop switches are series-connected to one E-Stop Safety Module, this test must be run individually for EACH switch. ES-FA-9AA 9 P/N 60606 rev. B ...

Page 10

... K1 CH S S4 S1 Figure 6. Model ES-FA-9AA E-Stop Safety Module enclosure dimensions 10 P/N 60606 rev. B ES-FA-9AA Repairs 118.0 mm (4.6") ! CAUTION ... Abuse of Module After Failure If an internal fault has occurred and the Module will not reset, do not tap, strike, or otherwise attempt to correct the fault by a physical impact to the housing ...

Page 11

... Tel: 763.544.3164 E-Stop Safety Module – Specifications applications, multiple contacts can also be switched in series (e.g., “dry switching”). Max. voltage: 60V Max. current: 300 mA Max. power VA) Max. voltage: 250V ac/dc Max. current Max. power: 200 W (1,500 VA) ES-FA-9AA 11 P/N 60606 rev. B ...

Page 12

... This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any other warranty either expressed or implied. P/N 60606 rev. B Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN USA 55441 • Phone: 763.544.3164 • www.bannerengineering.com • Email: sensors@bannerengineering.com ES-FA-9AA ® ...