ES-FA-9AA BANNER ENGINEERING, ES-FA-9AA Datasheet - Page 11

no-image

ES-FA-9AA

Manufacturer Part Number
ES-FA-9AA
Description
Module; Relay; Red LED; 24; UL Listed
Manufacturer
BANNER ENGINEERING
Datasheets

Specifications of ES-FA-9AA

Light Source
Red LED
Coil Voltage Vac Nom
24V
Coil Voltage Vdc Nom
24V
Contact Current Max
6A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
250V
Contact Configuration
3PST-NO
No. Of Poles
3
Lead Free Status / Rohs Status
RoHS Exempt Product
Supply Voltage and Current
Supply Protection Circuitry
Output Configuration
Output Response Time
Input Requirements
Minimum OFF-State
Recovery Time
Indicators
Construction
Mounting
Vibration Resistance
Operating Conditions
Dimensions
Banner Engineering Corp.
www.bannerengineering.com • Tel: 763.544.3164
Minneapolis, MN U.S.A.
24V ac/dc, +/- 10%; 50/60Hz
Power consumption: approx. 2W/2VA
Protected against transient voltages and reverse polarity
3 normally open (N/O) output channels
Each normally open output channel is a series connection of contacts from two forced-guided (positive-guided)
relays, K1-K2.
Contacts: AgNi, 5 µm gold-plated
Low Current Rating:
Caution: The  µm gold-plated contacts allow the switching of low current/low voltage. In these low-power
To preserve the gold plating on the contacts, the following max. values should not be exceeded at any time:
High Current Rating:
If higher loads must be switched through one or more of the contacts, the minimum and maximum values of the
contact(s) changes to:
Mechanical life: 50,000,000 operations
Electrical life: 150,000 operations (typical, @ 200 W (1,500 VA) switched power, resistive load
Note: Transient suppression is recommended when switching inductive loads. Install suppressors across load.
25 milliseconds typical
E-stop switch must have one or two normally closed contacts capable of switching 40 to 100mA @ 13 to
27V ac/dc.
Reset switch must have one normally open contact capable of switching 20 to 30mA @ 13 to 27V ac/dc.
250 ms
 green LED indicators:
Power ON
K1 energized
K2 energized
Polycarbonate housing. Rated NEMA 1; IEC IP40, Terminals IP20
Mounts to standard 35 mm DIN rail track. Safety Module must be installed inside an enclosure rated
NEMA 3 (IEC IP54), or better.
10 to 55Hz @ 0.35mm displacement per IEC 68-2-6
Temperature: 0° to +50°C (+32° to 122°F)
Max. Relative Humidity: 90% @ +50°C (non-condensing)
See Figure 6.
Min. voltage: 1V ac/dc
Min. current: 5 mA ac/dc
Min. power: 5 mW (5 mVA)
Min. voltage: 15V ac/dc
Min. current: 250 mA ac/dc
Min. power: 5 W (5 VA)
Never install suppressors across output contacts (see Warning, page ).
applications, multiple contacts can also be switched in series (e.g., “dry switching”).
Specifications
E-Stop Safety Module –
Max. voltage: 60V
Max. current: 300 mA
Max. power: 7 W (7 VA)
Max. voltage: 250V ac/dc
Max. current: 6 A
Max. power: 200 W (1,500 VA)