RCP-1000-12 Mean Well, RCP-1000-12 Datasheet - Page 2

Linear & Switching Power Supplies 720W 12V 60A W/PFC

RCP-1000-12

Manufacturer Part Number
RCP-1000-12
Description
Linear & Switching Power Supplies 720W 12V 60A W/PFC
Manufacturer
Mean Well
Datasheet

Specifications of RCP-1000-12

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
SPECIFICATION - Rack System
MODEL
FUNCTION
ENVIRONMENT
SAFETY &
EMC
(Note 4)
OTHERS
MODEL
OUTPUT
INPUT
FUNCTION
ENVIRONMENT
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
AUXILIARY POWER
REMOTE ON/OFF CONTROL
REMOTE SENSE
DC OK SIGNAL
AC FAIL SIGNAL
OUTPUT VOLTAGE TRIM
OVER TEMP WARNING
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
MODULE
RACK
OUTPUT VOLTAGE
MAX. OUTPUT CURRENT
MAX. OUTPUT POWER
VOLTAGE RANGE
FREQUENCY RANGE
AC CURRENT (Typ.)FOR EACH UNIT
LEAKAGE CURRENT
AUXILIARY POWER
REMOTE ON/OFF CONTROL
REMOTE SENSE
DC OK SIGNAL
AC FAIL SIGNAL
OUTPUT VOLTAGE TRIM
OVER TEMP WARNING
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
DIMENSION
PACKING
1000 ~ 3000W Front End Power System
Note.6
Note.5
RCP-1000-12
RCP-3K1U -12
RCP-1000-12
RCP-1UI or RCP-1UT
12V
180A
2160W
90 ~ 264VAC
47 ~ 63Hz
5V @ 0.3A
By electrical signal or dry contact
Compensate voltage drop on the load wiring up to 0.5V
The TTL signal out, refer to function manual
The TTL signal out, refer to function manual
Adjustment of output voltage, possible between 90 ~ 110% of rated output
Logic " High" for over temperature warning, refer to function manual
-20 ~ +60
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
43.4Khrs min.
295*127*41mm (L*W*H)
1.91Kg; 6pcs/12.5Kg/1.04CUFT
8.5A/115VAC
<3.5mA / 230VAC
5V @ 0.3A
By electrical signal or dry contact
Compensate voltage drop on the load wiring up to 0.5V. "Local Sense"should be connected in order to get the correct output voltage if the "Remote Sense"is not used
The TTL signal out, refer to function manual
The TTL signal out, refer to function manual
Adjustment of output voltage, possible between 90 ~ 110% of rated output
Logic " High" for over temperature warning, refer to function manual
-20 ~ +60
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
Rack 483.6*350.8*44(L*W*H)
11Kg; 1pcs/11Kg/2.67CUFT
0.02%/
0.02%/
(0 ~ 50 )
(0 ~ 50 )
(Refer to output load derating curve)
(Refer to output load derating curve)
MIL-HDBK-217F (25 )
I/P-FG:1.5KVAC
I/P-FG:1.5KVAC
127 ~ 370VDC
4.5A/230VAC
ON:short
ON:short
O/P-FG:0.7KVDC
O/P-FG:0.7KVDC
RCP-1000-24
RCP-3K1U -24
RCP-1000-24
24V
120A
2880W
10.5A/115VAC
OFF:open
OFF:open
5.5A/230VAC
RCP-1000-48
RCP-3K1U -48
RCP-1000-48
48V
63A
3024W
11A/115VAC
File Name:RCP series-SPEC 2010-10-18
R C P
5.5A/230VAC
s e r i e s

Related parts for RCP-1000-12