RCP-1000-12 Mean Well, RCP-1000-12 Datasheet
RCP-1000-12
Specifications of RCP-1000-12
Related parts for RCP-1000-12
RCP-1000-12 Summary of contents
Page 1
... Front End Power System SELECTION GUIDE Single Unit: RCP-1000 Rack: RCP- Whole System: RCP-3K1U - SPECIFICATION - Single Unit MODEL RCP-1000-12 DC VOLTAGE 12V RATED CURRENT 60A CURRENT RANGE 0 ~ 60A 720W RATED POWER RIPPLE & NOISE (max.) 150mVp-p Note.2 OUTPUT VOLTAGE ADJ. RANGE 11 ...
Page 2
... Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN61000-6-2 (EN50082-2), heavy industry level, criteria A MTBF 43.4Khrs min. OTHERS DIMENSION 295*127*41mm (L*W*H) 1.91Kg; 6pcs/12.5Kg/1.04CUFT PACKING SPECIFICATION - Rack System MODEL RCP-3K1U -12 MODULE RCP-1000-12 RACK RCP-1UI or RCP-1UT OUTPUT VOLTAGE 12V OUTPUT MAX. OUTPUT CURRENT 180A MAX. OUTPUT POWER 2160W Note.6 VOLTAGE RANGE 90 ~ 264VAC Note ...
Page 3
... PFC fosc : 110KHz PWM fosc : 90KHz RECTIFIERS ORING & DIODE FILTER CURRENT SHARE DETECTION CIRCUIT FUNCTION O.V.P. OPTIONAL RECTIFIERS CONTROL ON/OFF DETECTION CIRCUIT RECTIFIERS & FILTER File Name:RCP series-SPEC 2010-10- Unit: CURRENT SHARE V_TRIM ON/OFF AC_OK DC_OK T_ALARM AUX POWER (5V/0.3A) AUX GND ...
Page 4
... Front End Power System Mechanical Specification (Rack System RCP-1UT RCP-1UI 22 Module C 10 ADDRESS SWITCH - ADDRESS SWITCH - A 440 Air flow direction Module 466.2 483 Case No. 959A 14 1 CN500 + CN500 + Module File Name:RCP series-SPEC 2010-10- Unit:mm Fig1 25 13 Mounting Bracket 22 ...
Page 5
... T-ALARM ON/OFF-C 20 82Vrms +/-4V. High : when the input voltage in 82Vrms +/-4V. 80%+/-5% below the thermal shut down limit. Static Characteristics 100 Assignment Pin No. Assignment AC-OK DC-OK V-TRIM-C SCL 23 T-ALARM-C SDA 100 115 INPUT VOLTAGE (VAC) 60Hz File Name:RCP series-SPEC 2010-10- Ta=25 264 ...
Page 6
... Notice : The +S,-S have to be connected to the +V,-V terminals locally in order to get the correct output voltage if the remote sensing is not used RCP- Output Voltage Trimming Output voltage can be trimmed between 90~110% of its rated value by the following method V-TRIM-A 11 RCP-1U V-TRIM-B 18 V-TRIM 3.1 RCP-1000-12 Vout (%) 100 180K 240K 350K 560K ON/OFF A ON/OFF B ON/OFF C RCP-1U +V LOAD -V Sense lines should be twisted in pairs ...
Page 7
... When the internal temperature (TSW1 or TSW2 open) exceeds the limit of temperature alarm *Signal between function pin and "-S" Bus Interface Option 5.1 Addressing(A0,A1,A2) The DIP switch down position is logic level "1" and the up position is level "0". Address are applicable when modules RCP-1000 I C function are used OFF ...
Page 8
... Input power fail Output voltage is less than specification Internal temperature is over 60 . PSU turns on Temperature exceeds nominal operating limit. PSU turns off Failure of an internal fan Not used Not used Not used Output Voltage Output Current Internal Temperature File Name:RCP series-SPEC 2010-10- R/W ...