MPC8349VVALFB Freescale Semiconductor, MPC8349VVALFB Datasheet - Page 26

IC MPU POWERQUICC II 672-TBGA

MPC8349VVALFB

Manufacturer Part Number
MPC8349VVALFB
Description
IC MPU POWERQUICC II 672-TBGA
Manufacturer
Freescale Semiconductor
Series
PowerQUICC II PROr
Datasheet

Specifications of MPC8349VVALFB

Processor Type
MPC83xx PowerQUICC II Pro 32-Bit
Speed
667MHz
Voltage
1.3V
Mounting Type
Surface Mount
Package / Case
672-TBGA
Processor Series
MPC8xxx
Core
e300
Data Bus Width
32 bit
Development Tools By Supplier
MPC8349E-MITXE
Maximum Clock Frequency
667 MHz
Maximum Operating Temperature
+ 105 C
Mounting Style
SMD/SMT
I/o Voltage
1.8 V, 2.5 V, 3.3 V
Minimum Operating Temperature
0 C
Family Name
MPC83xx
Device Core
PowerQUICC II Pro
Device Core Size
32b
Frequency (max)
667MHz
Instruction Set Architecture
RISC
Supply Voltage 1 (typ)
1.3V
Operating Supply Voltage (max)
1.36V
Operating Supply Voltage (min)
1.24V
Operating Temp Range
0C to 105C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
672
Package Type
TBGA
Core Size
32 Bit
Program Memory Size
64KB
Cpu Speed
667MHz
Embedded Interface Type
I2C, SPI, USB, UART
Digital Ic Case Style
TBGA
No. Of Pins
672
Rohs Compliant
Yes
For Use With
MPC8349E-MITX-GP - KIT REFERENCE PLATFORM MPC8349EMPC8349E-MITXE - BOARD REFERENCE FOR MPC8349MPC8349EA-MDS-PB - KIT MODULAR DEV SYSTEM MPC8349E
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MPC8349VVALFB
Manufacturer:
AD
Quantity:
8 557
Part Number:
MPC8349VVALFB
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Ethernet: Three-Speed Ethernet, MII Management
8.2.2
This section describes the MII transmit and receive AC timing specifications.
8.2.2.1
Table 27
Figure 10
26
At recommended operating conditions with LV
TX_CLK clock period 10 Mbps
TX_CLK clock period 100 Mbps
TX_CLK duty cycle
TX_CLK to MII data TXD[3:0], TX_ER, TX_EN delay
TX_CLK data clock rise (20%–80%)
TX_CLK data clock fall (80%–20%)
Note:
1. The symbols for timing specifications follow the pattern of t
and t
(MT) for the time t
symbol is based on two to three letters representing the clock of a particular function. For example, the subscript of t
represents the MII(M) transmit (TX) clock. For rise and fall times, the latter convention is used with the appropriate letter:
R (rise) or F (fall).
(first two letters of functional block)(reference)(state)(signal)(state)
provides the MII transmit AC timing specifications.
shows the MII transmit AC timing diagram.
MPC8349EA PowerQUICC II Pro Integrated Host Processor Hardware Specifications, Rev. 12
MII AC Timing Specifications
MII Transmit AC Timing Specifications
TXD[3:0]
Parameter/Condition
TX_CLK
MTX
TX_EN
TX_ER
clock reference (K) going high (H) until data outputs (D) are invalid (X). In general, the clock reference
Table 27. MII Transmit AC Timing Specifications
Figure 10. MII Transmit AC Timing Diagram
t
MTXH
DD
/OV
t
DD
MTX
of 3.3 V ± 10%.
for outputs. For example, t
(first two letters of functional block)(signal)(state)(reference)(state)
t
t
MTKHDX
t
Symbol
MTXH/
MTXF
t
MTKHDX
t
t
t
t
MTXR
MTXF
MTX
MTX
t
MTX
1
t
MTXR
Min
1.0
1.0
35
1
MTKHDX
Typ
400
symbolizes MII transmit timing
40
5
Freescale Semiconductor
Max
4.0
4.0
65
15
for inputs
MTX
Unit
ns
ns
ns
ns
ns
%

Related parts for MPC8349VVALFB