20-101-1258 Rabbit Semiconductor, 20-101-1258 Datasheet - Page 31

COMPUTER SINGLE-BOARD BL4S160

20-101-1258

Manufacturer Part Number
20-101-1258
Description
COMPUTER SINGLE-BOARD BL4S160
Manufacturer
Rabbit Semiconductor
Datasheet

Specifications of 20-101-1258

Module/board Type
Single Board Computer Module
Product
Modules
Processor Type
Rabbit 4000
Sram
1 MB
Flash
2 MB
Timers
8 bit, 10 bit
Number Of I/os
20
Backup Battery
3 V Lithium Coin Type
Operating Voltage
9 V to 36 V
Board Size
96 mm x 146 mm x 16 mm
Description/function
Computer Module
For Use With/related Products
BL4S160
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
316-1171
3.4.1 A/D Converter Calibration
When you start to develop your application, run
SAMPLES\UserBlock
vertently write over them while running the sample programs.
To get the best results from the A/D converter, it is necessary to calibrate each mode
(single-ended, differential, and current) for each of its gains. It is imperative that you cali-
brate each of the A/D converter inputs in the same manner as they are to be used in the
application. For example, if you will be performing floating differential measurements or
differential measurements using a common analog ground, then calibrate the A/D con-
verter in the corresponding manner. The calibration table in software only holds calibra-
tion constants based on mode, channel, and gain.
be taken into account by calibrating using the same mode and gain setup as in the intended use.
Sample programs are provided to illustrate how to read and calibrate the various A/D
inputs for the three operating modes.
These sample programs are found in the
Section 4.2.3 for more information on these sample programs and how to use them.
BL4S100 User’s Manual
Single-Ended, unipolar
Differential, bipolar
4–20 mA
Mode
folder to save the factory calibration constants in case you inad-
ADC_RD_SE_UNIPOLAR.C ADC_CAL_SE_UNIPOLAR.C
ADC_RD_DIFF.C
ADC_RD_MA.C
ADC
Read
subdirectory in
USERBLOCK_READ_WRITE.C
Other factors affecting the calibration must
SAMPLES\BL4S1xx
ADC_CAL_DIFF.C
ADC_CAL_MA.C
Calibrate
in the
. See
29

Related parts for 20-101-1258