142-0701-441 Emerson Network Power, 142-0701-441 Datasheet - Page 251

no-image

142-0701-441

Manufacturer Part Number
142-0701-441
Description
RF Connectors SMA FRONT MOUNT JACK
Manufacturer
Emerson Network Power
Datasheet

Specifications of 142-0701-441

Product
Connector
Rf Series
SMA
Gender
Receptacle
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
BNC Twist-on Plugs and Jacks Field Installable
CABLE ASSEMBLY CAUTIONS:
CPFI-UG88-10
CPFI-UG78-2
CPFI-UG78-5
CPFI-UG88-1
CPFI-UG88-2
CPFI-UG88-3
CPFI-UG88-4
CPFI-UG88-5
CPFI-UG89-2
Series are designed for solid center conductor wire. RG-58 cable will need the
center conductor tin dipped (ONLY if it is not a solid center conductor). This is
necessary to provide extra support for step 5.
RG-MATV-59 cable will require caution when using the fingernail to rotate the
braids on cable types that include aluminum foil for the outer conductor. DO
NOT tear or rip the foil conductor to the 1/32" as suggested by step 3.
RG-62 cable includes trimming the filament to 9/16" as well. Make sure that
the filament does not unravel so that it protrudes past this dimension.
PART
NO.
Connectivity Solutions
RG-TFE-59, 62
BELDEN 8281
RG-MATV-59
RG-59, 62
RG-59, 62
RG-59, 62
CABLE
RG-58
TYPE
RG-6
RG-6
Tel: 800-247-8256
GAUGE
WIRE
22
18
20
22
20
20
18
22
22
.025 (0.64)
.040 (1.02)
.032 (0.81)
.025 (0.64)
.032 (0.81)
.032 (0.81)
.040 (1.02)
.025 (0.64)
.025 (0.64)
DECIMAL
WIRE
Fax: 507-833-6287
.220 (5.59)-.250 (6.35)
.270 (6.86)-.280 (6.35)
.185 (4.07)-.205 (5.21)
.220 (5.59)-.250 (6.35)
.272 (6.91)-.307 (7.80)
.220 (5.59)-.250 (6.35)
.270 (6.86)-.280 (7.11)
.185 (4.07)-.205 (5.21)
.220 (5.59)-.250 (6.35)
JACKET
Assembly Instructions
O.D.
www.EmersonNetworkPower.com/connectivity
INCHES (MILLIMETERS) • CUSTOMER DRAWINGS AVAILABLE ON REQUEST
1. Identify connector parts. (1 piece)
2. Trim cable as shown. Taking care not
3. Use the fingernail to rotate the outer
4. Gently insert the center conductor
5. Firmly push the cable home (a slight
to nick the center conductor or outer
braid.
braids clockwise such that 1/32" of the
insulation is bared. Then in the same
direction rub the stray braids flat. (Stray
or loose braids can cause shorts.)
down the back end of the connector,
feeding it into the guide hole. (If the
center conductor is not in place,
approximately 1/8" of the center
conductor—the part closest to the
dielectric —will still be viewable.)
clockwise twist may help with inser-
tion). Then screw the connector on the
cable in a clockwise direction until it is
snugly attached to the jacket.
251

Related parts for 142-0701-441