EP3CLS70F484I7N Altera, EP3CLS70F484I7N Datasheet - Page 17

no-image

EP3CLS70F484I7N

Manufacturer Part Number
EP3CLS70F484I7N
Description
IC FPGA CYCIII LS 70K 484-FBGA
Manufacturer
Altera
Series
Cyclone® IIIr

Specifications of EP3CLS70F484I7N

Number Of Logic Elements/cells
70208
Number Of Labs/clbs
4388
Total Ram Bits
3068928
Number Of I /o
278
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
484-FBGA
Family Name
Cyclone III LS
Number Of Logic Blocks/elements
70208
# I/os (max)
278
Frequency (max)
437.5MHz
Process Technology
65nm
Operating Supply Voltage (typ)
1.2V
Logic Cells
70208
Ram Bits
3068928
Operating Supply Voltage (min)
1.15V
Operating Supply Voltage (max)
1.25V
Operating Temp Range
-40C to 100C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
484
Package Type
FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP3CLS70F484I7N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP3CLS70F484I7N
Manufacturer:
ALTERA
0
Chapter 1: Cyclone III Device Data Sheet
Electrical Characteristics
Table 1–5. Cyclone III Devices Bus Hold Parameter
© January 2010 Altera Corporation
Bus-hold
low,
sustaining
current
Bus-hold
high,
sustaining
current
Bus-hold
low,
overdrive
current
Bus-hold
high,
overdrive
current
Bus-hold trip
point
Note to
(1) The bus-hold trip points are based on calculated input voltages from the JEDEC standard.
Parameter
Table
1–5:
V
(maximum)
V
(minimum)
0 V < V
0 V < V
IN
IN
Condition
> V
< V
IL
IL
IN
IN
Bus Hold
Bus hold retains the last valid logic state after the source driving it either enters the
high impedance state or is removed. Each I/O pin has an option to enable bus hold in
user mode. Bus hold is always disabled in configuration mode.
Table 1–5
OCT Specifications
Table 1–6
and voltage.
Table 1–6. Cyclone III Devices Series OCT without Calibration Specifications
OCT calibration is automatically performed at device power-up for OCT enabled
I/Os.
Series OCT without
calibration
< V
< V
CC IO
CC IO
Description
Min
0.3
lists bus hold specifications for Cyclone III devices.
lists the variation of OCT without calibration across process, temperature,
–8
8
1.2
–125
Max
125
0.9
0.375 1.125 0.68
Min
–12
12
V
CCIO
1.5
3.0
2.5
1.8
1.5
1.2
(Note 1)
–175
(V)
Max
175
Min
–30
30
Commercial
1.8
Max
±30
±30
+40
+50
+50
–200
Max
1.07
200
V
CC IO
Resistance Tolerance
(V)
Min
–50
0.7
50
2.5
Industrial and Automotive
–300
Max
300
1.7
Cyclone III Device Handbook, Volume 2
Min
–70
0.8
70
Max
±40
±40
±50
±50
±50
3.0
–500
Max
500
2
Min
–70
0.8
70
3.3
–500
Max
500
2
Unit
%
%
%
%
%
1–7
Unit
μA
μA
μA
μA
V

Related parts for EP3CLS70F484I7N