EP2C5F256I8 Altera, EP2C5F256I8 Datasheet - Page 157

IC CYCLONE II FPGA 5K 256-FBGA

EP2C5F256I8

Manufacturer Part Number
EP2C5F256I8
Description
IC CYCLONE II FPGA 5K 256-FBGA
Manufacturer
Altera
Series
Cyclone® IIr
Datasheet

Specifications of EP2C5F256I8

Number Of Logic Elements/cells
4608
Number Of Labs/clbs
288
Total Ram Bits
119808
Number Of I /o
158
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
256-FBGA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Gates
-
Other names
544-2132

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP2C5F256I8
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP2C5F256I8
Manufacturer:
ALTERA
Quantity:
8 000
Part Number:
EP2C5F256I8
Manufacturer:
ALTERA
0
Part Number:
EP2C5F256I8
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP2C5F256I8N
Manufacturer:
ALTERA42
Quantity:
532
Part Number:
EP2C5F256I8N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP2C5F256I8N
Manufacturer:
ALTERA
Quantity:
89
Part Number:
EP2C5F256I8N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP2C5F256I8N
Manufacturer:
ALTERA42
Quantity:
10 701
Duty Cycle
Distortion
Figure 5–8. Duty Cycle Distortion
Altera Corporation
February 2008
Notes to
(1)
(2)
(3)
(4)
(5)
(6)
f
t
V C O
A R E S E T
Table 5–54. PLL Specifications
These numbers are preliminary and pending silicon characterization.
The t
of them are switching outputs, how much they toggle, and whether or not they use programmable current strength.
If the VCO post-scale counter = 2, a 300- to 500-MHz internal VCO frequency is available.
This parameter is limited in the Quartus II software by the I/O maximum frequency. The maximum I/O frequency
is different for each I/O standard.
Cyclone II PLLs can track a spread-spectrum input clock that has an input jitter within ±200 ps.
For extended temperature devices, the maximum lock time is 500 us.
(3)
Symbol
Table
JITTER
specification for the PLL[4..1]_OUT pins are dependent on the I/O pins in its VCCIO bank, how many
5–54:
PLL internal VCO operating range
Minimum pulse width on
Duty cycle distortion (DCD) describes how much the falling edge of a
clock is off from its ideal position. The ideal position is when both the
clock high time (CLKH) and the clock low time (CLKL) equal half of the
clock period (T), as shown in
non-ideal falling edge from the ideal falling edge, such as D1 for the
falling edge A and D2 for the falling edge B
DCD for a clock is the larger value of D1 and D2.
DCD expressed in absolution derivation, for example, D1 or D2 in
Figure
percentage, and the percentage number is clock-period dependent. DCD
as a percentage is defined as:
Note (1)
CLKH = T/2
5–8, is clock-period independent. DCD can also be expressed as a
Falling Edge A
Parameter
(Part 2 of 2)
Ideal Falling Edge
Clock Period (T)
areset
D1
D2
Falling Edge B
signal.
DC Characteristics and Timing Specifications
Figure
CLKL = T/2
Cyclone II Device Handbook, Volume 1
5–8. DCD is the deviation of the
Min
300
10
(Figure
Typ
5–8). The maximum
1,000
Max
MHz
Unit
ns
5–67