EPM9320LC84-15 Altera, EPM9320LC84-15 Datasheet - Page 15

IC MAX 9000 CPLD 320 84-PLCC

EPM9320LC84-15

Manufacturer Part Number
EPM9320LC84-15
Description
IC MAX 9000 CPLD 320 84-PLCC
Manufacturer
Altera
Series
MAX® 9000r
Datasheet

Specifications of EPM9320LC84-15

Programmable Type
In System Programmable
Delay Time Tpd(1) Max
15.0ns
Voltage Supply - Internal
4.75 V ~ 5.25 V
Number Of Logic Elements/blocks
20
Number Of Macrocells
320
Number Of Gates
6000
Number Of I /o
60
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
84-PLCC
Voltage
3.3V/5V
Memory Type
EEPROM
Number Of Logic Elements/cells
20
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Features
-
Other names
544-2362-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EPM9320LC84-15
Manufacturer:
ALTERA
Quantity:
1 560
Part Number:
EPM9320LC84-15
Manufacturer:
ALTERA20
Quantity:
51
Part Number:
EPM9320LC84-15
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EPM9320LC84-15
Manufacturer:
ALTERA
0
Part Number:
EPM9320LC84-15 PLCC-84
Manufacturer:
ALTERA
0
Part Number:
EPM9320LC84-15 PLCC-84
Manufacturer:
ALTERA
0
Part Number:
EPM9320LC84-15N
Manufacturer:
ALTERA
Quantity:
4
Part Number:
EPM9320LC84-15N
Manufacturer:
ALTERA
Quantity:
1 125
Altera Corporation
A row interconnect channel can be fed by the output of the macrocell
through a 4-to-1 multiplexer that the macrocell shares with three column
channels. If the multiplexer is used for a macrocell-to-row connection, the
three column signals can access another row channel via an additional
3-to-1 multiplexer. Within any LAB, the multiplexers provide all
48 column channels with access to 32 row channels.
Row-to-I/O Cell Connections
Figure 8
and IOCs. An input signal from an IOC can drive two separate row
channels. When an IOC is used as an output, the signal is driven by a
10-to-1 multiplexer that selects the row channels. Each end of the row
channel feeds up to eight IOCs on the periphery of the device.
Figure 8. MAX 9000 Row-to-IOC Connections
Column-to-I/O Cell Connections
Each end of a column channel has up to 10 IOCs (see
signal from an IOC can drive two separate column channels. When an IOC
is used as an output, the signal is driven by a 17-to-1 multiplexer that
selects the column channels.
Row FastTrack
Interconnect
illustrates the connections between row interconnect channels
96
MAX 9000 Programmable Logic Device Family Data Sheet
96
96
Each IOC can drive up to
two row channels.
10
10
Each IOC is driven by
a 10-to-1 multiplexer.
IOC1
IOC8
Figure
9). An input
15

Related parts for EPM9320LC84-15