F3SJ-A0970P30 Omron, F3SJ-A0970P30 Datasheet - Page 53

no-image

F3SJ-A0970P30

Manufacturer Part Number
F3SJ-A0970P30
Description
F3SJ-A Safety Light Curtain, 30mm Resolution, 970 Mm Protected Height
Manufacturer
Omron
Datasheet
Wiring for connection with a controller F3SX-E-L2R (category 4) (PNP models only)
Note: 1. This wiring example is for category 4.
S1:
S2:
KM1, KM2: Magnetic contactor (LC1D)
RY1, RY2: Relay
M:
E1:
• Emergency stop switch can be connected.
• Door switch, two hand control, single beam, or relay unit can be used in combination with F3SX.
• Various settings can be changed and input/output terminals can be monitored using the setting support software for F3SX.
2. This example shows the connection when
3. When the F3SJ is series-connected, or 5 or more sets
auxiliary output 1 is in the standard setting (ON when
light is interrupted).
are connected to the total system of F3SX, power
must be supplied to F3SJ from external source.
For details, see instruction manual of F3SX.
Wiring for auto reset mode
15
Emergency stop switch
(direct opening contacts)(A165E, A22E)
Reset switch
3-phase motor
24 VDC power supply (S82K)
2
Y 1
24 VDC
KM1
KM2
24 VDC
24 VDC
S 2
8
9
Y 2
E1
Wiring when safety light curtain
E 1
S1
E1
11
Y 3
6
F3SJ is not used
A1
A2
16
1
Motor controller
24 VDC
SSC AS3
T11
14
3
M
11
12
E1
Main Module
Control Circuit
T12
13
4
(operation command)
24 VDC
AS2
T21
12
5
21
22
AS1
T22
10
7
SS1 SS2
RY1 RY2
Y1
24 VDC
0 V
Y2
RY1
RY2
S2
24 VDC
COM
FB
Y3
E1
Model F39-JC@A-L
cable for emitter
Model F39-JC@A-L
cable for emitter
15
2
8
9
Emitter
Emitter
11
6
16
1
14
3
L2 Module
Communication
line (+) (Gray)
Communication
line (+) (Gray)
Communication
line (−) (Pink)
13
F3SJ (1st unit)
4
F3SJ (2nd unit)
Communication
line (−) (Pink)
12
5
10
7
K2
K1
Receiver
Receiver
Model F39-JC@A-D
cable for receiver
11
12
Model F39-JC@A-D
cable for receiver
Relay Output Module
(R Module)
Fuse
KM1
23
24
KM2
33
34
F3SJ settings
• Auto reset mode
• External device monitoring
F3SX-E-L2R settings
• Manual reset mode
• Using feedback time
function disabled
monitoring function
AC
testing function is used
Test SW
Wiring when F3SJ's
F3SJ Ver.2
53

Related parts for F3SJ-A0970P30