F3SJ-A0970P30 Omron, F3SJ-A0970P30 Datasheet - Page 15

no-image

F3SJ-A0970P30

Manufacturer Part Number
F3SJ-A0970P30
Description
F3SJ-A Safety Light Curtain, 30mm Resolution, 970 Mm Protected Height
Manufacturer
Omron
Datasheet
Specifications
Main Units
F3SJ-A@@@@P14/P20/P25/P30/P55/N14/N20/N25/N30/N55
* Use of the Spatter Protection Cover causes a 10% maximum sensing distance attenuation.
Item
Sensor type
Version
Setting tool connection
Applicable safety category
Detection capability
Beam gap (P)
Number of beams (n)
Protective height (PH)
Lens diameter
Operating range *
Response time
(under stable light
incident
condition) (For
details, see
"Response Time"
on page 20.)
Startup waiting time
Power supply voltage (Vs)
Current
consumption (no
load)
Light source
(emitted wavelength)
Effective aperture angle
(EAA)
Control outputs
(OSSD)
Auxiliary output 1
(non-safety
output)
Auxiliary output 2
(non-safety
output, basic
system functions)
External indicator output
(non-safety output)
Output operation
mode
Model
ON to
OFF
OFF to
ON
Emitter
Receiver
PNP
outputs
NPN
outputs
PNP
output
NPN
output
PNP
output
NPN
output
Receiver
Emitter
outputs
outputs
PNP
NPN
(For details, refer to the instruction manual or User’s manual.)
Type 4 safety light curtain
Ver. 2
Connectable
Category 4, 3, 2, 1, or B
Opaque objects
14 mm in diameter
9 mm
26 to 180
245 to 1,631 mm
Diameter 5 mm
0.2 to 9 m (protective height 1,640 mm max.),
0.2 to 7 m (protective height 1,655 mm min.)
(Depending on the setting tool, the detection distance can be shortened to 0.5 m.)
1 set, 0245 to 983: 11 ms
to 17.5 ms max.
1,055 or higher: 20 ms to
25 ms max.
1 set, 0245 to 983: 44 ms
to 70 ms max.
1,055 or higher: 80 ms to
100 ms max.
2 s max. (2.2 s max. for series connection)
24 VDC 20% (ripple p-p10% max.)
Up to 50 beams: 76 mA max., 51 to 100 beams: 106 mA max., 101 to 150 beams: 130 mA max.,
151 to 180 beams: 153 mA max., 201 to 234 beams: 165 mA max.
Up to 50 beams: 68 mA max., 51 to 100 beams: 90 mA max., 101 to 150 beams: 111 mA max.,
151 to 180 beams: 128 mA max., 201 to 234 beams: 142 mA max.
Infrared LED (870 nm)
Based on IEC61496-2. Within 2.5 for both emitter and receiver when the detection distance is 3 m or over
Two PNP transistor outputs, load current 300 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension),
allowable capacity load 2.2 F, leak current 1 mA max.
(This can be different from traditional logic (ON/OFF) because safety circuit is used.)
Two NPN transistor outputs, load current 300 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension),
allowable capacity load 2.2 F, leak current 2 mA max.
(This can be different from traditional logic (ON/OFF) because safety circuit is used.)
One PNP transistor output, load current 300 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension),
leak current 1 mA max.
One NPN transistor output, load current 300 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension),
leak current 1 mA max.
One PNP transistor output, load current 50 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension),
leak current 1 mA max.
One NPN transistor output, load current 50 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension),
leak current 1 mA max.
Available indicators
Control outputs 1, 2:ON when receiving light
Auxiliary output 1:Inverse of control output signals (Operating mode can be changed with the setting tool.)
External indicator output 1:Inverse of control output signals for a basic system (Operating mode can be changed with the setting
tool.)
ON when muting/override for a muting system (Operating mode can be changed with the setting tool.)
Auxiliary output 2: Turns ON when the point of 30,000 operating hours is reached
(Operating mode can be changed with the setting tool.)
External indicator output 2:ON when lock-out for a basic system (Operating mode can be changed with the setting tool.)
ON when muting/override for a muting system (Operating mode can be changed with the setting tool.)
F3SJ-A@@@@P14
F3SJ-A@@@@N14
Incandescent lamp: 24 VDC, 3 to 7 W
LED lamp: Load current 10 mA to 300 mA max., leak current 1 mA max.
(To use an external indicator, an F39-JJ3N universal indicator cable or an F39-A01P@-PAC dedicated external indicator kit is
required.)
Opaque objects
20 mm in diameter
15 mm
16 to 166
245 to 2,495 mm
1 set, 0245 to 1,205: 10 ms
to 15 ms max.
1,235 or higher: 17.5 ms to
22.5 ms max.
1 set, 0245 to 1,205: 40 ms
to 60 ms max.
1,235 or higher: 70 ms to
90 ms max.
F3SJ-A@@@@P20
F3SJ-A@@@@N20
Opaque objects
25 mm in diameter
20 mm
13 to 125
260 to 2,500 mm
1 set, 0260 to 1,600: 10 ms
to 15 ms max.
1,620 or higher: 17.5 ms to
20.0 ms max.
1 set, 0260 to 1,600: 40 ms
to 60 ms max.
1,620 or higher: 70 ms to
80 ms max.
F3SJ-A@@@@N25
F3SJ-A@@@@P25
Opaque objects
30 mm in diameter
25 mm
10 to 100
1 set: 10 ms to 17.5 ms
max.
1 set: 40 ms to 70 ms
max.
F3SJ-A@@@@P30
F3SJ-A@@@@N30
Opaque objects
55 mm in diameter
50 mm
6 to 50
270 to 2,470 mm
1 set: 10 ms to 13 ms
max.
1 set: 40 ms to 52 ms
max.
F3SJ Ver.2
F3SJ-A@@@@P55
F3SJ-A@@@@N55
15

Related parts for F3SJ-A0970P30