F3SJ-A0970P30 Omron, F3SJ-A0970P30 Datasheet - Page 30

no-image

F3SJ-A0970P30

Manufacturer Part Number
F3SJ-A0970P30
Description
F3SJ-A Safety Light Curtain, 30mm Resolution, 970 Mm Protected Height
Manufacturer
Omron
Datasheet
Internal Indicators
Total View
*1. Lockout indicator (LOCKOUT) for models with the "-TS" suffix.
*2. In the TS model, this is a test indicator labeled TEST.
*3. This label is included with the F39-CN6 key cap for muting. Affix the label when the muting function is used.
1
2
3
4
5
6
7
8
9
10
No.
Light intensity level indicators
(LEVEL-1 to 5) (refer to page 31.)
Error mode indicators
(ERROR-A to C) (refer to page 31.)
Power indicator (POWER)
Interlock indicator (INTLK) *1
External device monitoring indicator
(EDM)
Muting input 1 indicator (MUTE1)
Blanking/Test indicator
(BLANKING/TEST) *2
Muting input 2 indicator (MUTE2)
OFF output indicator (OFF)
ON output indicator (ON)
Muting error indicator
(MUTING ERROR)
Blanking/Test indicator
(BLANKING/TEST) *2
2. Error mode indicators
1. Light intensity
level indicators
Internal Indicators
6. Blanking/Test indicator (Green)
4. Interlock indicator (Yellow) *1
5. External device monitoring
[Muting input 2 indicator] *2
indicator (Green)
[Muting input 1 indicator]
3. Power indicator (Green)
ERROR-C (Red)
ERROR-B (Red)
ERROR-A (Red)
LEVEL-5 (Green)
LEVEL-4 (Green)
LEVEL-3 (Orange)
LEVEL-2 (Orange)
LEVEL-1 (Orange)
ON
ON/
Blinking
ON
Blinking
ON
Blinking
ON
Blinking
ON
Blinking
ON
Blinking
ON
Blinking
ON
ON
Blinking
LEVEL
ERROR
POWER
30 dia.
BLANKING
5
4
3
2
1
C
B
A
INTLK
EDM
(TEST)
Indication status of LEVEL-1 to 5 shows the light intensity level status of the F3SJ.
Turns ON or blinks only on the sensor where the error occurred when the F3SJ enters
lockout. The error mode indicators turn OFF on sensors (emitters or receivers) where an
error did not occur, or on other series-connected sensors. The indication status of
ERROR-A to C shows the cause of the error. Affix the error mode label (included) near
the F3SJ to allow for quick troubleshooting when errors occur.
Turns ON while the power is ON.
Blinks when in maintenance mode.
Turns ON when F3SJ is in interlock state.
Blinks when under lockout.
Turns ON when an input is given to external
device monitoring input.
Not used
Turns ON when the blanking function and
warning zone function are enabled.
Blinks when external test is being
performed.
Turns ON when control output is OFF.
Blinks in the following states:
• Lockout state
• One or more beams are blocked in maintenance mode
Turns ON when safety output is ON.
Blinks when no beams are blocked in maintenance mode
Not used
Not used
Not used
Emitter
For basic system
*3
BLANKING
(TEST)
Receiver
ERROR
LEVEL
30 dia.
OFF
ON
C
B
A
5
4
3
2
1
LEVEL-5 (Green)
LEVEL-4 (Green)
LEVEL-3 (Orange)
LEVEL-2 (Orange)
LEVEL-1 (Orange)
ERROR-C (Red)
ERROR-B (Red)
ERROR-A (Red)
7. OFF-state indicator (Red)
8. ON-state indicator (Green)
9. Not used (Green)
10. Not used (Green)
The words in brackets ([ ]) represent the
indicator name for the muting system.
[Muting error indicator]
[Blanking/Test indicator] *2
Description
Turns ON when an input is given to muting
input 1.
Blinks during muting override.
Turns ON when an input is given to muting
input 2.
Blinks during muting override.
Turns ON when a muting error occurs.
Turns ON when the blanking function is
enabled.
Blinks when external test is being
performed.
2. Error mode indicators
1. Light intensity
For muting system
level indicators
F3SJ Ver.2
30

Related parts for F3SJ-A0970P30