DS1859B-020 Maxim Integrated Products, DS1859B-020 Datasheet - Page 16

IC RES TEMP 20/20K W/3MON 16-BGA

DS1859B-020

Manufacturer Part Number
DS1859B-020
Description
IC RES TEMP 20/20K W/3MON 16-BGA
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS1859B-020

Taps
256
Resistance (ohms)
20K
Number Of Circuits
2
Temperature Coefficient
50 ppm/°C Typical
Memory Type
Non-Volatile
Interface
I²C, 2-Wire Serial
Voltage - Supply
2.85 V ~ 5.5 V
Operating Temperature
-40°C ~ 95°C
Mounting Type
Surface Mount
Package / Case
16-CSBGA
Resistance In Ohms
20K
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS1859B-020
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS1859B-020+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS1859B-020+T&R
Manufacturer:
Maxim Integrated
Quantity:
10 000
Dual, Temperature-Controlled Resistors with
Internally Calibrated Monitors
Main Device (continued)
16
LOCATION
MEMORY
(hex)
Bit 7
Bit 7
____________________________________________________________________
70
71
4
3
2
1
0
6
5
4
3
2
1
0
6
5
4
EEPROM/
SRAM
SRAM
SRAM
R/W
R/W
R
R
DEFAULT
SETTING
(hex)
0
0
0
0
0
NAME OF LOCATION
Alarm flags
Alarm flags
MON2U
MON3U
MON1hi
MON1lo
MON2hi
MON2lo
MON3hi
MON3lo
TMPhi
TMPlo
V
V
CC
CC
X
X
hi
lo
This bit goes high after a MON2 update has
occurred for the corresponding measurement
in bytes 66h to 67h. This bit can be written to
a 0 by the user and monitored to verify that a
conversion has occurred.
This bit goes high after a MON3 update has
occurred for the corresponding measurement
in bytes 68h to 69h. This bit can be written to
a 0 by the user and monitored to verify that a
conversion has occurred.
This alarm flag goes high when the upper limit
of the temperature setting is violated.
This alarm flag goes high when the lower limit
of the temperature setting is violated.
This alarm flag goes high when the upper limit
of the V
This alarm flag goes high when the lower limit
of the V
This alarm flag goes high when the upper limit
of the MON1 setting is violated.
This alarm flag goes high when the lower limit
of the MON1 setting is violated.
This alarm flag goes high when the upper limit
of the MON2 setting is violated.
This alarm flag goes high when the lower limit
of the MON2 setting is violated.
This alarm flag goes high when the upper limit
of the MON3 setting is violated.
This alarm flag goes high when the lower limit
of the MON3 setting is violated.
CC
CC
setting is violated.
setting is violated.
FUNCTION

Related parts for DS1859B-020