AD7734BRUZ Analog Devices Inc, AD7734BRUZ Datasheet - Page 23

no-image

AD7734BRUZ

Manufacturer Part Number
AD7734BRUZ
Description
IC ADC 24BIT 4-CH 28-TSSOP
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD7734BRUZ

Data Interface
DSP, MICROWIRE™, QSPI™, Serial, SPI™
Number Of Bits
24
Sampling Rate (per Second)
15.4k
Number Of Converters
1
Power Dissipation (max)
100mW
Voltage Supply Source
Analog and Digital
Operating Temperature
-40°C ~ 105°C
Mounting Type
Surface Mount
Package / Case
28-TSSOP (0.173", 4.40mm Width)
Resolution (bits)
24bit
Sampling Rate
15.4kSPS
Input Channel Type
Single Ended
Supply Voltage Range - Analog
4.75V To 5.25V
Supply Current
13.5µA
Number Of Elements
1
Resolution
24Bit
Architecture
Delta-Sigma
Sample Rate
3.05MSPS
Input Polarity
Unipolar/Bipolar
Input Type
Voltage
Rated Input Volt
5/10/±5/±10V
Differential Input
No
Power Supply Requirement
Analog and Digital
Single Supply Voltage (typ)
5V
Single Supply Voltage (min)
4.75V
Single Supply Voltage (max)
5.25V
Dual Supply Voltage (typ)
Not RequiredV
Dual Supply Voltage (min)
Not RequiredV
Dual Supply Voltage (max)
Not RequiredV
Power Dissipation
100mW
Integral Nonlinearity Error
±0.0045%FSR
Operating Temp Range
-40C to 105C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
28
Package Type
TSSOP
Input Signal Type
Single-Ended
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
EVAL-AD7734EBZ - BOARD EVALUATION FOR AD7734
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7734BRUZ
Manufacturer:
ADI
Quantity:
1 000
Part Number:
AD7734BRUZ
Manufacturer:
AMI
Quantity:
6 224
Part Number:
AD7734BRUZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7734BRUZ-REEL7
Manufacturer:
ATMEL
Quantity:
12 000
Part Number:
AD7734BRUZ-REEL7
Manufacturer:
ADI
Quantity:
1 000
Reset
The AD7734 can be reset by the RESET pin or by writing a reset
sequence to the AD7734 serial interface.
The reset sequence is N × 0 + 32 × 1, which could be the data
sequence 00h + FFh + FFh + FFh + FFh in a byte-oriented
interface. The AD7734 also features a power-on reset with a
trip point of 2 V and goes to the defined default state after
power-on.
It is the system designer’s responsibility to prevent an unwanted
write operation to the AD7734. The unwanted write operation
could happen when a spurious clock appears on the SCLK while
the CS pin is low. It should be noted that on system power-on, if
the AD7734 interface signals are floating or undefined, the part
can be inadvertently configured into an unknown state. This
could be easily overcome by initiating either a hardware reset
event or a 32 ones reset sequence as the first step in the system
configuration.
Access the AD7734 Registers
All communications to the part start with a write operation to
the communications register followed by either reading or
writing the addressed register.
In a simultaneous read-write interface (such as SPI), write 0 to
the AD7734 while reading data.
Figure 16 shows the AD7734 interface read sequence for the
ADC status register.
DOUT
SCLK
RDY
DIN
CS
COMMUNICATIONS
Figure 17. Serial Interface Signals—Single Conversion Command and 16-Bits Data Reading
REGISTER
WRITE
38h
REGISTER
WRITE
MODE
40h
CONVERSION TIME
Rev. 0 | Page 23 of 32
COMMUNICATIONS
Single Conversion and Reading Data
When the mode register is being written, the ADC status byte is
cleared and the RDY pin goes high, regardless of its previous
state. When the single conversion command is written to the
mode register, the ADC starts the conversion on the channel
selected by the address of the mode register. After the
conversion is completed, the data register is updated, the mode
register is changed to idle mode, the relevant RDY bit is set, and
the RDY pin goes low. The RDY bit is reset and the RDY pin
returns high when the relevant channel data register is
being read.
Figure 17 shows the digital interface signals executing a single
conversion on Channel 0, waiting for the RDY pin to go low,
and reading the Channel 0 data register.
REGISTER
WRITE
48h
Figure 16. Serial Interface Signals—Registers Access
DOUT
SCLK
DIN
CS
DATA
READ DATA REGISTER
(00h)
COMMUNICATIONS
REGISTER
WRITE
DATA
(00h)
ADC STATUS
REGISTER
READ
AD7734

Related parts for AD7734BRUZ