AD7734BRUZ Analog Devices Inc, AD7734BRUZ Datasheet - Page 20

no-image

AD7734BRUZ

Manufacturer Part Number
AD7734BRUZ
Description
IC ADC 24BIT 4-CH 28-TSSOP
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD7734BRUZ

Data Interface
DSP, MICROWIRE™, QSPI™, Serial, SPI™
Number Of Bits
24
Sampling Rate (per Second)
15.4k
Number Of Converters
1
Power Dissipation (max)
100mW
Voltage Supply Source
Analog and Digital
Operating Temperature
-40°C ~ 105°C
Mounting Type
Surface Mount
Package / Case
28-TSSOP (0.173", 4.40mm Width)
Resolution (bits)
24bit
Sampling Rate
15.4kSPS
Input Channel Type
Single Ended
Supply Voltage Range - Analog
4.75V To 5.25V
Supply Current
13.5µA
Number Of Elements
1
Resolution
24Bit
Architecture
Delta-Sigma
Sample Rate
3.05MSPS
Input Polarity
Unipolar/Bipolar
Input Type
Voltage
Rated Input Volt
5/10/±5/±10V
Differential Input
No
Power Supply Requirement
Analog and Digital
Single Supply Voltage (typ)
5V
Single Supply Voltage (min)
4.75V
Single Supply Voltage (max)
5.25V
Dual Supply Voltage (typ)
Not RequiredV
Dual Supply Voltage (min)
Not RequiredV
Dual Supply Voltage (max)
Not RequiredV
Power Dissipation
100mW
Integral Nonlinearity Error
±0.0045%FSR
Operating Temp Range
-40C to 105C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
28
Package Type
TSSOP
Input Signal Type
Single-Ended
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
EVAL-AD7734EBZ - BOARD EVALUATION FOR AD7734
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7734BRUZ
Manufacturer:
ADI
Quantity:
1 000
Part Number:
AD7734BRUZ
Manufacturer:
AMI
Quantity:
6 224
Part Number:
AD7734BRUZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7734BRUZ-REEL7
Manufacturer:
ATMEL
Quantity:
12 000
Part Number:
AD7734BRUZ-REEL7
Manufacturer:
ADI
Quantity:
1 000
AD7734
Mode Register
8 Bits, Read/Write Register, Address 38h–3Bh, Default Value 00h
The mode register configures the part and determines its operating mode. Writing to the mode register clears the ADC status register, sets
the RDY pin to a logic high level, exits all current operations, and starts the mode specified by the mode bits.
The AD7734 contains only one mode register. The two LSBs of the address are used for writing to the mode register to specify the channel
selected for the operation determined by the MD2 to MD0 bits. Only the address 38h must be used for reading from the mode register.
Bit
Mnemonic
Default
Bit
7–5
4
3
2
1
0
MD2
0
0
0
0
1
1
1
1
0
1
0
0
1
1
Mnemonic
MD2–MD0
CLKDIS
DUMP
Cont RD
24/16 BIT
CLAMP
MD1
0
1
MD0
0
1
0
1
0
1
0
1
Mode
Idle Mode
Continuous Conversion Mode
Single Conversion Mode
Power-Down (Standby) Mode
ADC Zero-Scale Self-Calibration
For Future Use
Channel Zero-Scale System Calibration
Channel Full-Scale System Calibration
Bit 7
MD2
0
Description
Mode Bits. These three bits determine the AD7734 operation mode. Writing a new value to the mode bits will
exit the part from the mode in which it has been operating and place it in the newly requested mode
immediately. The function of the mode bits is described in more detail below.
Master Clock Output Disable. When this bit is set to 1, the master clock is disabled from appearing at the
MCLKOUT pin and the MCLKOUT pin is in a high impedance state. This allows turning off the MCLKOUT as a
power saving feature. When using an external clock on MCLKIN, the AD7734 continues to have internal clocks
and will convert normally regardless of the CLKDIS bit state. When using a crystal oscillator or ceramic resonator
across the MCLKIN and MCLKOUT pins, the AD7734 clock is stopped and no conversions can take place when
the CLKDIS bit is active. The AD7734 digital interface can still be accessed using the SCLK pin.
DUMP Mode. When this bit is reset to 0, the channel status register and channel data register will be addressed
and read separately. When the DUMP bit is set to 1, the channel status register will be followed immediately by a
read of the channel data register regardless of whether the status or data register has been addressed through
the communication register. The continuous read mode will always be dump mode reading of the channel
status and data register, regardless of the dump bit value (see the Digital Interface Description section for more
details).
When this bit is set to 1, the AD7734 will operate in the continuous read mode (see the Digital Interface
Description section for more details).
The Channel Data Register Data Width Selection Bit. When set to 1, the channel data registers will be 24 bits
wide. When set to 0, the channel data registers will be 16 bits wide.
This bit determines the channel data register’s value when the analog input voltage is outside the nominal input
voltage range. When the CLAMP bit is set to 1, the channel data register will be digitally clamped either to all 0s
or all 1s when the analog input voltage goes outside the nominal input voltage range. When the CLAMP bit is
reset to 0, the data registers reflect the analog input voltage even outside the nominal voltage range (see the
Analog Input’s Extended Voltage Range section).
Bit 6
MD1
0
Bit 5
MD0
0
Rev. 0 | Page 20 of 32
Bit 4
CLKDIS
0
Address Used for Mode Register Write Specifies:
The First Channel to Start Converting
Channel to Convert
Channel Conversion Time Used for the ADC Self-Calibration
Channel to Calibrate
Channel to Calibrate
Bit 3
DUMP
0
Bit 2
0
Cont RD
Bit 1
24/16 BIT
0
Bit 0
CLAMP
0