MAX19707ETM+ Maxim Integrated Products, MAX19707ETM+ Datasheet - Page 24

IC ANLG FRONT END 45MSPS 48-TQFN

MAX19707ETM+

Manufacturer Part Number
MAX19707ETM+
Description
IC ANLG FRONT END 45MSPS 48-TQFN
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX19707ETM+

Number Of Bits
10
Number Of Channels
4
Power (watts)
84.6mW
Voltage - Supply, Analog
3V
Voltage - Supply, Digital
3V
Package / Case
48-TQFN Exposed Pad
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
10-Bit, 45Msps, Ultra-Low-Power
Analog Front-End
Shutdown mode offers the most dramatic power sav-
ings by shutting down all the analog sections of the
MAX19707 and placing the Rx ADC digital outputs in
tri-state mode. When the Rx ADC outputs transition
from tri-state to ON, the last converted word is placed
on the digital outputs. The Tx DAC previously stored
data is lost when coming out of shutdown mode. The
wake-up time from shutdown mode is dominated by the
time required to charge the capacitors at REFP, REFN,
and COM. In internal reference mode and buffered
external reference mode, the wake-up time is typically
85.2µs to enter Rx mode and 28.2µs to enter Tx mode.
In idle mode, the reference and clock distribution cir-
cuits are powered, but all other functions are off. The
Table 9. Offset Control Bits for I and Q Channels (IOFFSET or QOFFSET Mode)
Note: For transmit full-scale of ±400mV: 1 LSB = (800mV
Table 10. Common-Mode Select
(COMSEL Mode)
24
CM1
0
0
1
1
IO5/QO5
______________________________________________________________________________________
1
1
1
1
1
1
0
0
0
0
0
0
BITS IO5–IO0 WHEN IN IOFFSET MODE, BITS QO5–QO0 WHEN IN QOFFSET MODE
CM0
0
1
0
1
Tx DAC OUTPUT COMMON MODE (V)
IO4/QO4
1
1
1
0
0
0
0
0
0
1
1
1
1.05 (Default)
0.95
0.80
0.70
IO3/QO3
1
1
1
0
0
0
0
0
0
1
1
1
P-P
/ 1023) = 0.7820mV.
IO2/QO2
1
1
1
0
0
0
0
0
0
1
1
1
Rx ADC outputs are forced to tri-state. The wake-up
time is 9.8µs to enter Rx mode and 6.4µs to enter Tx
mode. When the Rx ADC outputs transition from tri-
state to ON, the last converted word is placed on the
digital outputs.
In standby mode, the reference is powered, but the rest
of the device functions are off. The wake-up time from
standby mode is 13.7µs to enter Rx mode and 24µs to
enter Tx mode. When the Rx ADC outputs transition
from tri-state to active, the last converted word is
placed on the digital outputs.
In addition to the external Tx-Rx control, the MAX19707
also features SLOW and FAST modes for switching
between Rx and Tx operation. In FAST Tx mode, the Rx
ADC core is powered on but the ADC core digital out-
puts are tri-stated on the D0–D9 bus; likewise, in FAST
Rx mode, the transmit DAC core is powered on but the
DAC core digital inputs are tri-stated on the D0–D9 bus.
The switching time between Tx to Rx or Rx to Tx is FAST
because the converters are on and do not have to
recover from a power-down state. In FAST mode, the
switching time between Rx to Tx and Tx to Rx is 0.5µs.
IO1/QO1
1
1
0
1
0
0
0
0
1
0
1
1
FAST and SLOW Rx and Tx Modes
IO0/QO0
1
0
1
0
1
0
0
1
0
1
0
1
OFFSET 1 LSB =
(VFS
0mV (Default)
-31 LSB
-30 LSB
-29 LSB
29 LSB
30 LSB
31 LSB
-2 LSB
-1 LSB
P-P
1 LSB
2 LSB
0mV
/ 1023)

Related parts for MAX19707ETM+