PAXLPV00 Red Lion Controls, PAXLPV00 Datasheet - Page 4

METER PROCESS VOLT 3 1/2-DIGIT

PAXLPV00

Manufacturer Part Number
PAXLPV00
Description
METER PROCESS VOLT 3 1/2-DIGIT
Manufacturer
Red Lion Controls
Series
PAX®LITEr
Type
Voltmeterr
Datasheets

Specifications of PAXLPV00

Measuring Range
0 ~ 25 VDC
Display Style
Red Characters, Black Background
Display Type
LED
Display Face Size
3.80" L x 1.95" W (96.5 x 49.5mm)
Display Digits
3.5
Display Digits - Height
0.560" (14.22mm)
Backlight
Without
Mounting Type
Panel Mount
Termination
Screw Terminals
Voltage - Supply
85 ~ 250VAC
No. Of Digits / Alpha
3-1/2
Meter Function
DC Process
Meter Range
± 0V To ± 25V
Digit Height
14.2mm
Power Consumption
6VA
Operating Temperature Range
0°C To +60°C
Supply Voltage Ac, Min
85V
Accuracy
±0.05% %
Common Mode Rejection Ratio
100 dB
Connection Type
Cage-Clamp
Cut Out, Panel
3.62×1.77 "
Dimensions
4.2"L×3.8"W×1.95"H
Display Digit Height
0.56 "
Function
Voltage
Number Of Digits
3-1/2
Primary Type
Electronic
Range, Measurement
±25 VDC
Response Time
1 sec.
Temperature, Operating
0 to 60 °C
Voltage, Input
±25 VDC
Voltage, Supply
85 to 250 VAC
Weight
0.65 lbs.
Character Size
0.56"
Display Font Color
Red
Rohs Compliant
NA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
na, Contains lead / RoHS non-compliant
Other names
RLC113
Installation
unit is intended to be mounted into an enclosed panel. Prepare the panel cutout
to the dimensions shown. Remove the panel latch from the unit. Slide the panel
applying power. To access the switches, remove the meter base from the case by
firmly squeezing and pulling back on the side rear finger tabs. This should lower
the latch below the case slot (which is located just in front of the finger tabs). It
is recommended to release the latch on one side, then start the other side latch.
Set-Up DIP Switches
of switches are used for calibrating the meter. The values of these switches are
discussed in section 5.0 Calibrating the Meter.
selection of decimal points and backlight annunciator. Selecting “ON” position
enables the function.
1.0 I
2.0 S
The PAX meets NEMA 4X/IP65 requirements when properly installed. The
The meter has switches that must be checked and/or changed prior to
Two banks of DIP switches are located inside the meter. The 10 position bank
The bank of 4 switches located near the front display are used for the
SWITCH
NSTALLING THE
1
2
3
4
ETTING THE
Backlight Annunciator for Units Label
gasket over the rear of the unit to the back of
Decimal Point 1 (000.0)
Decimal Point 2 (00.00)
Decimal Point 3 (0.000)
the bezel. The unit should be installed
fully assembled. Insert the unit into
FUNCTION
the panel cutout.
S
WITCHES
M
ETER
4
so that the tabs of the panel latch engage in the slots on the case. The panel latch
should be engaged in the farthest forward slot possible. To achieve a proper seal,
tighten the latch screws evenly until the unit is snug in the panel (Torque to
approximately 7 in-lbs [79N-cm]). Do not over-tighten the screws.
Installation Environment
operating temperature and provides good air circulation. Placing the unit near
devices that generate excessive heat should be avoided.
Do NOT use solvents. Continuous exposure to direct sunlight may accelerate the
aging process of the bezel.
While holding the unit in place, push the panel latch over the rear of the unit
The unit should be installed in a location that does not exceed the maximum
The bezel should be cleaned only with a soft cloth and neutral soap product.
REAR TERMINALS
Main
Circuit
Board
FRONT DISPLAY
PANEL CUT-OUT
ON
4
3
2
1
D.P./ BACKLIGHT
OFFSET
10
1
2
3
4
5
6
7
8
9
ON
OFFSET
SPAN
SPAN