METER PROCESS VOLT 3 1/2-DIGIT

PAXLPV00

Manufacturer Part Number
PAXLPV00
Description
METER PROCESS VOLT 3 1/2-DIGIT
Manufacturer
Red Lion Controls
Series
PAX®LITEr
Type
Voltmeterr
Datasheets

Specifications of PAXLPV00

Measuring Range
0 ~ 25 VDC
Display Style
Red Characters, Black Background
Display Type
LED
Display Face Size
3.80" L x 1.95" W (96.5 x 49.5mm)
Display Digits
3.5
Display Digits - Height
0.560" (14.22mm)
Backlight
Without
Mounting Type
Panel Mount
Termination
Screw Terminals
Voltage - Supply
85 ~ 250VAC
No. Of Digits / Alpha
3-1/2
Meter Function
DC Process
Meter Range
± 0V To ± 25V
Digit Height
14.2mm
Power Consumption
6VA
Operating Temperature Range
0°C To +60°C
Supply Voltage Ac, Min
85V
Accuracy
±0.05% %
Common Mode Rejection Ratio
100 dB
Connection Type
Cage-Clamp
Cut Out, Panel
3.62×1.77 "
Dimensions
4.2"L×3.8"W×1.95"H
Display Digit Height
0.56 "
Function
Voltage
Number Of Digits
3-1/2
Primary Type
Electronic
Range, Measurement
±25 VDC
Response Time
1 sec.
Temperature, Operating
0 to 60 °C
Voltage, Input
±25 VDC
Voltage, Supply
85 to 250 VAC
Weight
0.65 lbs.
Character Size
0.56"
Display Font Color
Red
Rohs Compliant
NA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
na, Contains lead / RoHS non-compliant
Other names
RLC113
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net
MODEL PAXLPV - PAX LITE PROCESS VOLT METER
GENERAL DESCRIPTION
measurement of process variables. With its high sensitivity and programmability,
the PAX Lite Process Volt Meter can be set up for a wide variety of applications.
In most plants the PAXLPV can be used for 90 to 95% of Process Volt meter
needs for readout of pressure, flow, temperature, level and other variables. The
meter has been specifically designed for harsh industrial environments. With
NEMA 4X/IP65 sealed bezel and extensive testing of noise effects to CE
requirements, the meter provides a tough yet reliable application solution. This
allows the PAXLPV to be used in dirty, hostile environments and in wash-down
areas. The 3½-digit bi-polar display (minus sign displayed when voltage is
negative) features 0.56" (14.2 mm) high, 7-segment LEDs for easy reading.
DIMENSIONS In inches (mm)
The premium features of the PAX Lite Series can now be applied to
4
Note: Recommended minimum clearance (behind the panel) for mounting clip installation is
2.1" (53.4) H x 5.0" (127) W.
1
SAFETY SUMMARY
literature or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
All safety related regulations, local codes and instructions that appear in the
installation and operation of the unit.
WIDE SPAN & OFFSET SCALING RANGE
3 1/2-DIGIT, 0.56" (14.2 mm) HIGH LED READOUT
24 VDC EXCITATION SUPPLY
OVER-RANGE INDICATION
SELECTABLE DECIMAL POINTS
NEMA 4X/IP65 SEALED FRONT BEZEL
OPTIONAL CUSTOM UNITS OVERLAY W/BACKLIGHT
±25 VOLT DC MAXIMUM INPUT
Read complete instructions prior to
CAUTION: Risk of Danger.
CAUTION: Risk of electric shock.
Bulletin No. PAXLPV-D
Drawing No. LP0570
Released 9/08

PAXLPV00 Summary of contents

Page 1

Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net MODEL PAXLPV - PAX LITE PROCESS VOLT METER 4 GENERAL DESCRIPTION The premium features of the PAX Lite Series can now be applied to measurement of process variables. With its high ...

Page 2

ABLE F ONTENTS Ordering Information . . . . . . . . . . . . . . . . . . . 2 General Meter Specifications ...

Page 3

G M ENERAL ETER 1. DISPLAY: 3 1/2-digit, 0.56" (14.2 mm) high, 7-segment LED, (-) minus sign displayed when current or voltage is negative. Decimal points inserted before 1st, 2nd, or 3rd least significant digits by DIP switch selection. 2. ...

Page 4

I NSTALLING THE Installation The PAX meets NEMA 4X/IP65 requirements when properly installed. The unit is intended to be mounted into an enclosed panel. Prepare the panel cutout to the dimensions shown. Remove the panel latch from the unit. ...

Page 5

W IRING THE WIRING OVERVIEW Electrical connections are made via screw-clamp terminals located on the back of the meter. All conductors should conform to the meter’s voltage and current ratings. All cabling should conform to appropriate standards of good ...

Page 6

S CALING THE DESCRIPTION OF OPERATION The PAX Lite Process Volt Meter consists of a digital volt meter combined with an analog scaling circuit (shown above). Input voltage can be reversed in polarity resulting in negative numerical readout with ...

Page 7

... The Company’s option. The Company disclaims all liability for any affirmation, promise or representation with respect to the products. The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against damages, claims, and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC ...

Page 8

... D.P. switch S1 ON and replace unit in case. Red Lion Controls BV Printerweg 3821 AD Amersfoort Tel +31 (0) 334 723 225 Fax +31 (0) 334 893 793 VOLT = Red Lion Controls AP Unit 101, XinAn Plaza Building 13, No.99 Tianzhou Road ShangHai, P.R. China 200223 Tel +86 21 6113-3688 Fax +86 21 6113-3683 ...