H7CX-A11-N AC100-240 Omron, H7CX-A11-N AC100-240 Datasheet - Page 32

COUNTER DGTL SPDT 100-240VAC

H7CX-A11-N AC100-240

Manufacturer Part Number
H7CX-A11-N AC100-240
Description
COUNTER DGTL SPDT 100-240VAC
Manufacturer
Omron

Specifications of H7CX-A11-N AC100-240

Count Rate
30Hz or 5kHz Selectable
Number Of Digits/alpha
6
Input Type
Voltage, Switch Closure, Transistor Switch
Output Type
Switch Closure
Voltage - Supply
100 V ~ 240 VAC
Display Type
LCD Backlit
No. Of Digits / Alpha
4
Digit Height
10mm
Power Consumption
9.4VA
Counting Speed
5kHz
Operating Temperature Range
-10°C To +55°C
Character Size
9mm
Supply Voltage Min
100VAC
Panel Cutout Width
45mm
Meter Function
Counter
Rohs Compliant
Yes
Connector Type
11-Pin Socket
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H7CXA11NAC100240
Z3041
H7CX-A@-N
Tachometer
ON Count Alarm Set Values for Outputs 1 and 2 (OUT1
and OUT2) (on1a and on2a)
Set the ON count alarm values for the outputs 1 and 2.
The limit can be set to between 0
1000 (0 times) and 9999
1000
(9,999,000 times). Only the underlined values are set. The alarm will
be disabled if 0 is set.
If the total ON count of instantaneous output 1 or 2 exceeds the alarm
set value, e3 will be displayed on the Timer to indicate that the output
ON count alarm value was exceeded. Refer to Self-diagnostic
Function on page page 36 for information on the e3 display.
ON Count Monitor Values for Outputs 1 and 2 (OUT1 and
OUT2) (on1c and on2c)
The monitor value for output 1 or 2 is only displayed. It cannot be set.
The output ON count will be 1,000 times the displayed value.