H7CX-A11-N AC100-240 Omron, H7CX-A11-N AC100-240 Datasheet - Page 20

COUNTER DGTL SPDT 100-240VAC

H7CX-A11-N AC100-240

Manufacturer Part Number
H7CX-A11-N AC100-240
Description
COUNTER DGTL SPDT 100-240VAC
Manufacturer
Omron

Specifications of H7CX-A11-N AC100-240

Count Rate
30Hz or 5kHz Selectable
Number Of Digits/alpha
6
Input Type
Voltage, Switch Closure, Transistor Switch
Output Type
Switch Closure
Voltage - Supply
100 V ~ 240 VAC
Display Type
LCD Backlit
No. Of Digits / Alpha
4
Digit Height
10mm
Power Consumption
9.4VA
Counting Speed
5kHz
Operating Temperature Range
-10°C To +55°C
Character Size
9mm
Supply Voltage Min
100VAC
Panel Cutout Width
45mm
Meter Function
Counter
Rohs Compliant
Yes
Connector Type
11-Pin Socket
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H7CXA11NAC100240
Z3041
20
H7CX-A@-N
Counter
Operation in Run Mode
I/O Functions for Counter Operation
• Set values for each digit as required using the U
1-stage Preset Counter
2-stage Preset Counter with
Absolute Value Setting
2-stage Preset Counter with
Forecast Value Setting
• Present Value
• Set Values
• Forecast Set Value
• Present Value
• Set Values (Set Value 1 and Set Value 2)
Shows the present count value.
Set the set values.
Set the deviation for the set value.
Shows the present count value.
Set the set values.
When the present value reaches the set value (set
value 1 or set value 2), a signal is output according
to the specified output mode.
Present value
Set value
Present value
Set value 1
Present value
Set value 2
Present value
Set value
Present value
Forecast Set Value
Total and Preset Counter
Batch Counter
• Present Value/Set Value
• Batch Count Value
• Batch Count Set Value
(D)
• Present Value/Set Value
• Total Count Value
Same as 1-stage preset counter.
Shows the number of times the count has been
Set the batch count set value.
When the batch count value reaches the batch
completed for the present value.
count set value, batch output (OUT1) turns ON.
Same as 1-stage preset counter.
Shows the present total count value.
Keys. (U Key only for 6-digit models.)
Present value
Set value
Total count value
Present value
Set value
Batch count value
Batch count set value
Dual Counter
Twin Counter
• Present Values 1 and 2
• Set Values 1 and 2
• Dual Count Value
• Dual Count Set Value
• CP1/CP2 Present Value
Shows the present count value 1 or 2.
Setting for present value 1 or 2.
Shows the sum of the CP1 present value and
Set the dual count set value.
When the dual count value reaches the dual
Show the present count values for CP1 and
CP2 present value when the dual count
calculating mode is ADD and shows the value
obtained by subtracting the CP2 present
value from the CP1 present value when the
dual count calculating mode is SUB.
count set value, signals are output according
to the specified output mode.
CP2 present values respectively.
Dual count value
Dual count
set value
CP1 present value
CP2 present value
Present value 1
Set value 1
Present value 2
Set value 2