H7CX-A11-N AC100-240 Omron, H7CX-A11-N AC100-240 Datasheet - Page 23

COUNTER DGTL SPDT 100-240VAC

H7CX-A11-N AC100-240

Manufacturer Part Number
H7CX-A11-N AC100-240
Description
COUNTER DGTL SPDT 100-240VAC
Manufacturer
Omron

Specifications of H7CX-A11-N AC100-240

Count Rate
30Hz or 5kHz Selectable
Number Of Digits/alpha
6
Input Type
Voltage, Switch Closure, Transistor Switch
Output Type
Switch Closure
Voltage - Supply
100 V ~ 240 VAC
Display Type
LCD Backlit
No. Of Digits / Alpha
4
Digit Height
10mm
Power Consumption
9.4VA
Counting Speed
5kHz
Operating Temperature Range
-10°C To +55°C
Character Size
9mm
Supply Voltage Min
100VAC
Panel Cutout Width
45mm
Meter Function
Counter
Rohs Compliant
Yes
Connector Type
11-Pin Socket
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H7CXA11NAC100240
Z3041
Note: 1. The full scale (FS) for H7CX 4-digit models is 9999.
Output
mode
setting
2. When the present value reaches 999999, it returns to 0.
3. Counting cannot be performed during reset/reset 1 input.
4. If reset/reset 1 is input while one-shot output is ON, one-shot output turns OFF.
5. If there is power failure while output is ON, output will turn ON again when the power supply has recovered.
6. Do not use the counter function in applications where the count may be completed (again) while one-shot output is ON.
7. The setting range is 0 to 999,999 (0 to 9,999 for 4-digit models).
For one-shot output, output will turn ON again for the duration of the output time setting once the power supply has recovered.
Q
A
P
Set value 2
Set value 1
Set value 2
Set value 1
Set value 2
Set value 1
999999
reset 1
Reset/
OUT1
OUT2
999999
reset 1
Reset/
OUT1
OUT2
999999
reset 1
Reset/
OUT1
OUT2
0
0
0
UP
Input mode
DOWN
Self-holding
output
UP/DOWN A, B, C
One-shot output from OUT1
Self-holding
output
output from OUT2
One-shot
H7CX-A@-N
The present value
display does not
change during the
one-shot output time
period, but the actual
count returns to the
reset start status.
The output will return
to one-shot mode.
The outputs repeat
one-shot operation.
OUT1 self-holding
output turns OFF after
the OUT2 one-shot
output time.
The OUT1 one-shot
output time is
independent of OUT2.
The present value
continues to increase/
decrease for the one-
shot output time, but
returns to the reset
start status after the
one-shot output time
has elapsed.
The outputs repeat
one-shot operation.
OUT1 self-holding
output turns OFF after
the OUT2 one-shot
output time.
The OUT1 one-shot
output time is
independent of OUT2.
The present value
display and OUT1
self-holding output is
held until reset/reset 1
is input.
OUT1 and OUT2 are
independent.
(The one-shot output time ca
set in the range 0.01 to 99.9
count completion
Operation after
Counter
23