CUB5R000 Red Lion Controls, CUB5R000 Datasheet - Page 11

COUNTER/RATE IND DUAL REFL DISPL

CUB5R000

Manufacturer Part Number
CUB5R000
Description
COUNTER/RATE IND DUAL REFL DISPL
Manufacturer
Red Lion Controls
Series
CUB5r
Type
Counter/Rate Indicatorr
Datasheet

Specifications of CUB5R000

Count Rate
20kHz
Number Of Digits/alpha
8
Input Type
Voltage, Switch Closure, Transistor Switch
Voltage - Supply
9 V ~ 28 V
Display Type
LCD Non-Backlit
No. Of Digits / Alpha
8
Digit Height
11.7mm
Counting Speed
20kHz
Operating Temperature Range
-35°C To +75°C
Signal Input Type
Current
Character Size
0.46"
Ip/nema Rating
IP65 / NEMA 4X
Accuracy
±0.01% %
Connection Type
Screw
Counter Type
Up⁄Down & Rate
Cut Out, Panel
2.68×1.3 "
Dimensions
2.95"L×1.86"W×1.54"H
Display Digit Height
0.46 "
Display Range
-9999999 to +99999999
Frequency, Operating
20 kHz (Max.)
Function
Counter/Rate Indicator
Material, Casing
Plastic
Memory Type
EEPROM
Mounting Type
Panel
Number Of Digits
8
Output Type
Relay
Primary Type
Electronic
Range, Measurement
-9999999 to 999999
Special Features
Programmable
Standards
CE Marked
Temperature, Operating, Range
-35 to +75 °C
Terminal Type
Screw Terminal
Termination
Screw Terminal
Voltage, Supply
9 to 28 VDC
Weight
3.2 Oz.
Memory
Nonvolatile EEPROM
User Input
Programmable, Connect to Common to Activate Function
Rate Minimum Input Frequency
0.01 Hz
Rate Maximum Frequency
20 kHz
Operating Temperature
0 to 60°C
Panel Cutout
2.68" × 1.30"
Counter Supply Voltage
9-28VDC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Output Type
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
RLC121

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CUB5R000
Manufacturer:
Red Lion Controls
Quantity:
135
SPn ASN
"
Setpoint 1 is completely programmed, the display returns to
steps for Setpoint 2 if both Setpoints are used in the application.
available is dependent on the Setpoint option module installed.
selected, the unit returns to
Output Module is installed in the meter. Some parameters in the menu will not
appear depending on the Setpoint Assignment and Setpoint Output Action. The
Setpoint Parameter Availability chart below illustrates this.
SPt SEL
SP2 Enb
n
6.4 MODULE 4 - S
" in the following parameters reflects the chosen Setpoint number. After
Select the Setpoint Output to be programmed, starting with Setpoint 1. The
Select
Select
Select the display to which the Setpoint is assigned.
The Setpoint Output Parameters are only active when an optional Setpoint
Count A
NO
YES
to exit the Setpoint programming module. The number of Setpoints
to enable Setpoint 2 and access the setup parameters. If
SEL
SPt SEL
SETPOINT 2 ENABLE (SP2 Only)
4-SEtPt
Setpoint
Setpoint Output
NO
NO
Select
SPn P-UP
Power-up
State
SETPOINT ASSIGNMENT
PARAMETER
SPn tOUt
SPn VAL
SPn OUt
SPn LIt
SPn P-UP
SPn tYPE
SPn StbY
SPn AUtO
SP1 OFF2
SP2 OFF1
SPn rSt
SPn ChC
* BOUNDARY Setpoint Action not applicable for Counter B Assignment
SETPOINT SELECT
SPt SEL
Count A
NO
NO
SP2 Enb
SP2 Only
Setpoint 2
Enable
SPn tYPE
Boundary
Setpoint
Type
Setpoint Output Time-out Value
Setpoint Value
Setpoint Output Logic
Setpoint Annunciator
Setpoint Output Power-up State
Setpoint Boundary Type
Standby Operation (Low acting only)
Counter Auto Reset
SP1 Output Off at SP2 (SP1 only)
SP2 Output Off at SP1 (SP2 only)
Output Reset with Manual Reset
Change Display Color w/ Output State
and Setpoint 2 is disabled.
SP1
YES
Count b
SPn ASN
Assignment
Setpoint
SPn StbY
DESCRIPTION
Operation
Standby
Setpoint
SP2
ETPOINT
SETPOINT PARAMETER AVAILABILITY
SPn ACt
SPt SEL
rAtE
Setpoint
Output
Action
SPn AUtO
Auto Reset
PARAMETER MENU
Counter
. Repeat
NO
O
SPn tOUt
TIMED OUT
Setpoint
Time-out
is
Output
UTPUT
COUNTER ASSIGNMENT (A or B) *
SP1 OFF2
SP1 Output
t-OUt
Off at SP2
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
SP1 Only
No
No
No
Output
11
SPn ACt
chart. Boundary output action is not applicable for Counter B assignment.
SPT ACTION DESCRIPTION
BOUNDARY
The parameter selects the action of the Setpoint Output as described in the
LAtCH
t-OUt
bOUNd
SPn VAL
bOUNd
Setpoint
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
Value
SP2 OFF1
SP2 Output
P
Off at SP1
SP2 Only
Output
ARAMETERS
LAtCH
Latched Output Mode
Timed Output Mode
Boundary Mode
(High Acting Type)
Boundary Mode
(Low Acting Type)
LATCH
LAtCH
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
Output Logic
SPn OUt
Setpoint
SETPOINT OUTPUT ACTION
Output Reset
with Manual
SPn rSt
Setpoint
Reset
TIMED OUT
t-OUt
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
LAtCH
SPn LIt
Annunciator
Setpoint
Change Display
RATE ASSIGNMENT
OUTPUT ACTIVATES
SPn ChC
Output State
Color with
Backlight
Unit Only
When Count =
When Count =
When Count
When Count
(
BOUNDARY
Setpoint
Setpoint
Setpoint
Setpoint
4-SEtPt
bOUNd
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
t-OUt


LATCH
P P r r o o
LAtCH
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
)
No
No
No
No
OUTPUT DEACTIVATES
At Manual Reset
Output Time-Out
(if
bOUNd
After Setpoint
When Count
When Count
SPn rSt
< Setpoint
Setpoint
=
YES
)