Specifications of NHD-2.7-12864UCY3

Pixel Density
128 x 64
Viewing Area (w X H)
66 mm x 33 mm
Operating Voltage
2.8 V
Operating Current
53 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Illumination Color
Yellow
Viewing Angle
80 deg
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
 
Quality Information 
High Temperature storage 
Low Temperature storage 
High Temperature 
Operation 
Low Temperature 
Operation 
High Temperature / 
Humidity Operation 
Thermal Shock resistance 
Vibration test 
Atmospheric Pressure test  Test the endurance of the display by 
Static electricity test 
Note 1: No condensation to be observed. 
Note 2: Conducted after 2 hours of storage at 25⁰C, 0%RH. 
Note 3:
Evaluation Criteria: 
1: Display is fully functional during operational tests and after all tests, at room temperature. 
2: No observable defects. 
3: Luminance >50% of initial value. 
4: Current consumption within 50% of initial value 
 
 
 
Precautions for using OLEDs/LCDs/LCMs 
See Precautions at www.newhavendisplay.com/specs/precautions.pdf 
 
Warranty Information and Terms & Conditions 
http://www.newhavendisplay.com/index.php?main_page=terms 
 
Newhaven Display International, Inc. reserves the right to alter this product or specification at any time without notification. 
 
Test Item 
 
Test performed on product itself, not inside a container
Test the endurance of the display at high 
storage temperature. 
Test the endurance of the display at low 
storage temperature. 
Test the endurance of the display by 
applying electric stress (voltage & current) 
at high temperature. 
Test the endurance of the display by 
applying electric stress (voltage & current) 
at low temperature. 
Test the endurance of the display by 
applying electric stress (voltage & current) 
at high temperature with high humidity. 
Test the endurance of the display by 
applying electric stress (voltage & current) 
during a cycle of low and high 
temperatures.  
Test the endurance of the display by 
applying vibration to simulate 
transportation and use. 
applying atmospheric pressure to simulate 
transportation by air. 
Test the endurance of the display by 
applying electric static discharge. 
Content of Test 
[11] 
+90⁰C , 240hrs
‐40⁰C , 240hrs
+85⁰C 240hrs
‐40⁰C , 240hrs
+60⁰C , 90% RH ,  240hrs 
‐40⁰C,30min ‐> 25⁰C,5min ‐> 
85⁰C,30min = 1 cycle 
100 cycles 
10‐22Hz , 15mm amplitude. 
22‐500Hz, 1.5G 
30min in each of 3 directions 
X,Y,Z 
115mbar, 40hrs
VS=800V, RS=1.5kΩ, CS=100pF 