NHD-2.7-12864UCY3 Newhaven Display, NHD-2.7-12864UCY3 Datasheet

LCD OLED GRAPHIC 128 X 64 YLW

NHD-2.7-12864UCY3

Manufacturer Part Number
NHD-2.7-12864UCY3
Description
LCD OLED GRAPHIC 128 X 64 YLW
Manufacturer
Newhaven Display
Datasheet

Specifications of NHD-2.7-12864UCY3

Pixel Density
128 x 64
Viewing Area (w X H)
66 mm x 33 mm
Operating Voltage
2.8 V
Operating Current
53 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Illumination Color
Yellow
Viewing Angle
80 deg
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
 
 
NHD‐2.7‐12864UCY3 
OLED Display Module 
  
NHD‐   
2.7‐ 
12864‐   
UC‐ 
Y‐ 
3‐ 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Newhaven Display 
2.7” diagonal size 
128 x 64 pixel resolution 
Model   
Emitting Color: Yellow 
+3V power supply 
 
 
 
 
 
 
 
 
nhtech@newhavendisplay.com  
 
 
 
 
 
 
 
 
www.newhavendisplay.com 
Newhaven Display International, Inc. 
2511 Technology Drive, Suite 101 
Elgin IL, 60124 
Ph: 847‐844‐8795 
 
[1] 
nhsales@newhavendisplay.com 
Fax: 847‐844‐8796 

Related parts for NHD-2.7-12864UCY3

NHD-2.7-12864UCY3 Summary of contents

Page 1

... NHD‐2.7‐12864UCY3  OLED Display Module     NHD‐    Newhaven Display  2.7‐    2.7” diagonal size  12864‐    128 x 64 pixel resolution  UC‐    ...

Page 2

Document Revision History  Revision  Date  0  5/1/2011            Functions and Features  • 128 x 64 pixel resolution  • Built‐in SSD1325 controller  • Parallel or serial MPU interface  • Single, low voltage power supply  • RoHS compliant    Description  Initial Product Release  [2]  Changed by  ‐  ...

Page 3

... Mechanical Drawing           [3]      NHD‐2.7‐12864UCY3  ...

Page 4

Interface Description    Parallel Interface:   Pin No.  Symbol  External  Connection  1  VSS  Power Supply  2  VDD  Power Supply  3  NC  ‐ 4  D/C  MPU  5  R/W or /WR  MPU  6  E or /RD  MPU  7‐14  DB0 – DB7  MPU  15  NC  ‐ 16  /RES  MPU  17  /CS  MPU  18  NC  ‐ ...

Page 5

MPU U Interface Pin n Assignment t Summery  Data/C Command Inte Bu us  Inter rface  D7  D D6  D5  D4  D3  8‐bit  6800  8‐bit  8080  SPI  Tie LOW      Wir ring Diag rams       erface D2  D[7:0]  E D[7:0]  /RD NC  ...

Page 6

Electrical Characteristics    Item  Operating Temperature Range  Storage Temperature Range  Supply Voltage  Supply Current (logic)  Supply Current (display)  Sleep Mode Current  “H” Level input  “L” Level input  “H” Level output  “L” Level output      Optical Characteristics  Item  Viewing Angle – Vertical (top)  Viewing Angle – Vertical (bottom)  Viewing Angle – Horizontal (left)  Viewing Angle – Horizontal (right)  Contrast Ratio  Response Time (rise)  Response Time (fall)  Brightness  Lifetime  Note:  Lifetime  at  typical  temperature  is  based  on  accelerated  high‐temperature  operation.  Lifetime  is  ...

Page 7

Built‐in SSD1325 controller    Instruction Table  Instruction  D/C  HEX  DB7  DB6  Set Column  0  15  0  Address  0  A[5:0]  *  0  B[5:0]  *  Set Row Address  0  75  0  0  A[6:0]  *  A6  0  B[6:0]  *  B6  Set Contrast  0  81  1  Control  0  A[6:0]  *  A6  ...

Page 8

Set Display ON/  0  AE~AF  1  OFF  Set VCOMH  0  BE  1  Voltage  0  A[5:0]  *  Set Precharge  0  BC  1  Voltage  0  A[7:0]  A7  A6  Set Phase Length  0  B1  1  0  A[3:0]  *  0  A[7:4]  A7  A6  Set Row Period  0  B2  1  0  A[7:0]  A7  ...

Page 9

MPU Interface    For detailed timing information, see datasheet: http://www.newhavendisplay.com/app_notes/SSD1325.pdf     6800‐MPU Parallel Interface  The parallel interface consists of 8 bi‐directional data pins, R/W, D/C, E, and /CS.  A LOW on R/W indicates write operation, and HIGH on R/W indicates read operation.  A LOW on D/C indicates “Command” read or write, and HIGH on D/C indicates “Data” read or write.  The E input serves as data latch signal, while /CS is LOW. Data is latched at the falling edge of E signal.    Function  Write Command  Read Status  Write Data  Read Data          8080‐MPU Parallel Interface  The parallel interface consists of 8 bi‐directional data pins, /RD, /WR, D/C, and /CS.  A LOW on D/C indicates “Command” read or write, and HIGH on D/C indicates “Data” read or write.  A rising edge of /RS input serves as a data read latch signal while /CS is LOW.  A rising edge of /WR input serves as a data/command write latch signal while /CS is LOW.    Function  Write Command  Read Status  Write Data  Read Data    Alternatively, /RD and /WR can be kept stable while /CS serves as the data/command latch signal.  Function  Write Command  Read Status  Write Data  Read Data    ...

Page 10

Serial Interface  The serial interface consists of serial clock SCLK, serial data SDIN, D/C, and /CS.  D0 acts as SCLK and D1 acts as SDIN. D2 should be left open. D3~D7, E, and R/W should be connected to GND.  Function  Write Command  Write Data  SDIN is shifted into an 8‐bit shift register on every rising edge of SCLK in the order of D7, D6,…D0.  D/C is sampled on every eighth clock and the data byte in the shift register is written to the GDRAM or  command register in the same clock.  Note: Read is not available in serial mode.      For detailed protocol information, see datasheet: http://www.newhavendisplay.com/app_notes/SSD1325.pdf           Example Initialization Sequence:  Set_Display_On_Off_12864(0x00);    Set_Display_Clock_12864(0x91);    Set_Multiplex_Ratio_12864(0x3F);    Set_Display_Offset_12864(0x4C);    Set_Start_Line_12864(0x00);    Set_Master_Config_12864(0x00);    Set_Remap_Format_12864(0x50);                ...

Page 11

Quality Information  Test Item  High Temperature storage  Test the endurance of the display at high  storage temperature.  Low Temperature storage  Test the endurance of the display at low  storage temperature.  High Temperature  Test the endurance of the display by  Operation  applying electric stress (voltage & current)  at high temperature.  Low Temperature  Test the endurance of the display by  Operation  applying electric stress (voltage & current)  at low temperature.  High Temperature /  Test the endurance of the display by  Humidity Operation  applying electric stress (voltage & current)  at high temperature with high humidity.  Thermal Shock resistance  Test the endurance of the display by  applying electric stress (voltage & current)  during a cycle of low and high  temperatures.   Vibration test  Test the endurance of the display by  applying vibration to simulate  transportation and use.  Atmospheric Pressure test  Test the endurance of the display by  applying atmospheric pressure to simulate  transportation by air.  Static electricity test  Test the endurance of the display by  ...