SR1500ALSASRNA Intel (CPU), SR1500ALSASRNA Datasheet - Page 19

no-image

SR1500ALSASRNA

Manufacturer Part Number
SR1500ALSASRNA
Description
Manufacturer
Intel (CPU)
Datasheet

Specifications of SR1500ALSASRNA

Lead Free Status / RoHS Status
Not Compliant
Monthly Specification Update
Problem
Implication
Status
Workaround
Problem
Implication
Status
Workaround
Problem
Implication
Status
Workaround
19.
20.
21.
setup.
System SR1500AL show a “Changes in Hardware or Drivers
Detected” error message during WHQL ACPI stress testing.
HSC and BMC versions intermittently not seen in BIOS
Intel
POST LEDs don’t turn off after operating system loads.
BMC and HSC revision information is intermittently missing from BIOS setup.
HSC and BMC information is not easily found.
This erratum is fixed in BIOS release R0057 and later releases.
Users will need to use the DOS utility, ‘fwpiaupd.exe’ to probe and get the
backplane HSC information. Boot to DOS and using the fwpiaupd.exe utility
which is used to flash the BMC and HSC code onto the server system, enter
the following command: “fwpiaupd –i –address={c0, c2}” where c0= primary
backplane address and c2= secondary backplane address. This will provide
you with the operational code revision for the HSC on each backplane.
To retrieve the BMC version information, use the same ‘fwpiaupdt.exe’ utility
with the following command: “fwpiaupdt –i –address=20”.
While running HCT 12.1 ACPI stress device I/O or any HCT test that needs to
reboot, the system will show the following error message: “Changes in
Hardware or Drivers Detected”.
This message may prevent users from receiving Microsoft WHQL certification.
This erratum is fixed in BIOS release R0045 and later releases.
If system is shut down and restarted, rather than rebooted, between tests, the
error does not appear.
The POST Code LEDs at the rear of the system do not turn off once POST
completes and the operating system loads. The POST code LEDs will show
[Green Red Green Red] at the rear of the system.
User may believe that since there are LEDs lit on the baseboard that an error
has occurred.
This erratum is fixed in BIOS release R0057 and later releases.
None.
®
Server Boards S5000PAL/S5000XAL and Intel
Intel Confidential
Enterprise Platforms and Services Marketing
®
Server
17