SR1500ALSASRNA Intel (CPU), SR1500ALSASRNA Datasheet - Page 14

no-image

SR1500ALSASRNA

Manufacturer Part Number
SR1500ALSASRNA
Description
Manufacturer
Intel (CPU)
Datasheet

Specifications of SR1500ALSASRNA

Lead Free Status / RoHS Status
Not Compliant
Monthly Specification Update
Problem
Implication
Status
Workaround
Problem
Implication
Status
Workaround
Problem
Implication
Status
Workaround
12
4. Power supply population errors may not appear in the SEL.
5. Fan 5 may report a reading of 0 RPM after the BMC is updated.
6. The BMC may not respond to the IPMI command, Send Message
sent via LAN.
The BMC will not give any indication if a single power supply is improperly
installed in a redundant chassis.
Some chassis require power supplies to be installed in specific slots if a single
power supply is installed.
This erratum may be fixed in a future firmware revision.
None.
After a BMC update, fan 5 may not return an accurate reading until AC power
is cycled.
Intel
of 0 RPM for this sensor. The BMC may respond as though this fan has failed
and fan redundancy is lost. This will cause the system fault LED and fan status
LED to indicate a failure for this sensor, and the fans will run in a high speed
‘boost’ state.
This erratum may be fixed in a future firmware revision.
AC cycle the system again and the system should run normally.
The BMC may not respond correctly to a Send Message command from the
LAN channel to the IPMB channel. This issue only affects an IPMI 2.0 based
RMCP+ session, not an IPMI 1.5 based RMCP session.
Remote IPMI over LAN software cannot forward commands to the IPMB bus.
This erratum is fixed in BMC release 50 and later releases.
Software developers should use IPMI 1.5 based sessions to bridge commands
to the IPMB channel.
®
System Management Software and other software may display a reading
Intel Confidential
Enterprise Platforms and Services Marketing