10.
11.
12.
events.
Fans may run faster than expected after exiting BIOS setup.
System fault LED may report incorrect status for some
Fan removal does not generate a SEL event.
Some system fans may run faster after exiting BIOS setup using the ‘save and
exit’ option.
The system may generate more fan noise than normal.
This erratum may be fixed in a future firmware revision.
The system must be AC cycled, or allowed to boot to the OS and then reset, to
restore fans to their normal speeds.
The system fault LED may report incorrect status for some events. The proper
LED state is described in the server board TPS, but some events may not
reflect the states described in the TPS.
The user may receive an incorrect indication via the system fault LED. The
user should verify the system state by looking at the SEL. No event is reported
with a less severe status than expected, but events may appear with a higher
severity status.
This erratum will be fixed in a future firmware version.
None.
Fan removal does not trigger a fan failure event.
Simulating a fan failure by fan removal will not work.
This erratum may be fixed in a future firmware revision.
None.