DSCC FORM 2234
APR 97
Interim electrical parameters,
Static burn-in I, method 1015
Interim electrical parameters,
Static burn-in II, method 1015
Interim electrical parameters,
Dynamic burn-in I, method 1015
Interim electrical parameters,
Final electrical parameters,
Group A test requirements,
Group B end-point electrical
Group C end-point electrical
Group D end-point electrical
Group E end-point electrical
1/
2/
3/
4/
5/
6/
method 5004
(4.2.1a)
method 5004 (4.2.1b)
(4.2.1a)
method 5004 (4.2.1b)
(4.2.1a)
method 5004 (4.2.1b)
method 5004
method 5005 (4.4.1)
parameters, method 5005 (4.4.2)
parameters, method 5005 (4.4.3)
parameters, method 5005 (4.4.4)
parameters, method 5005 (4.4.5)
Blank spaces indicate tests are not applicable.
PDA applies to subgroup 1 (see 4.2.3). For device classes S and V, PDA applies to subgroups 1 and 7 (see 4.2.3).
The burn-in shall meet the requirements of 4.2.1a herein.
On all class S lots, the device manufacturer shall maintain read-and-record data (as a minimum on disk) for burn-in
electrical parameters (group A, subgroup 1), in accordance with test method 5004 of MIL-STD-883. For pre-burn-in and
interim electrical parameters, the read-and-record requirements are for delta measurements only.
Delta limits shall be required only on table IA, subgroup 1. The delta values shall be computed with reference to the
previous interim electrical parameters. The delta limits are specified in table IIB.
The device manufacturer may, at his option, either complete subgroup 1 electrical parameter measurements, including
delta measurements, within 96 hours after burn-in completion (removal of bias) or may complete subgroup 1 electrical
measurements without delta measurements within 24 hours after burn-in completion (removal of bias). When the
manufacturer elects to perform the subgroup 1 electrical parameter measurements without delta measurements, there is
no requirement to perform the pre-burn-in electrical tests (first interim electrical parameters test in table IIA).
DEFENSE SUPPLY CENTER COLUMBUS
Test requirements
MICROCIRCUIT DRAWING
COLUMBUS, OHIO 43218-3990
STANDARD
method 5005, table I)
1, 2, 3, 4, 7, 8, 9, 10,
(in accordance with
1, 2, 3, 7, 8, 9 2/
Subgroups 1/
MIL-STD-883,
class M
Device
1, 2, 3
1, 2, 3
1, 7, 9
TABLE IIA. Electrical test requirements.
11
3/
3/
3/
Required 6/
1, 2, 3, 4, 7,
8, 9, 10, 11
class B 2/
1, 2, 7, 9
required
1 2/ 5/
required
1, 2 5/
Device
1, 7, 9
2/ 6/
1, 2
Not
Not
1
SIZE
A
Required 4/
Required 4/
Required 4/
1, 2, 3, 4, 7,
1, 2, 3, 7, 8,
9, 10, 11 5/
8, 9, 10, 11
class S 2/
1, 2, 7, 9
1 2/ 5/
Device
1, 2, 3
1, 7, 9
1 5/
MIL-PRF-38535, table III)
1 5/
REVISION LEVEL
2/
1
Subgroups 1/
(in accordance with
C
1, 2, 3, 7, 8, 9,
1, 2, 3, 4, 7, 8,
10, 11 2/ 6/
Required 6/
1, 2, 3 5/
9, 10, 11
required
required
1 2/ 5/
class Q
Device
1, 2, 3
1, 7, 9
Not
Not
1
SHEET
1, 2, 3, 4, 7, 8,
1, 2, 3, 7, 8, 9,
5962-90985
1, 2, 3, 7,8, 9,
Required 4/
Required 4/
Required 4/
10, 11 5/
10, 11 2/
9, 10, 11
1 2/ 5/
class V
Device
1, 2, 3
1, 7, 9
1 5/
1 5/
18
1