Volume 1 of 1
Table 6: SPDO Registers
PNX17XX_SER_1
Preliminary data sheet
Bit
Offset 0x10 9000
31:5
0
1
2
3
4
Offset 0x10 9004
31
30
Symbol
Reserved
BUF1_EMPTY
BUF2_EMPTY
HBE (bandwidth error)
UNDERRUN
BUF1_ACTIVE
RESET
TRANS_ENABLE
5.2 Register Table
SPDO_STATUS
SPDO_CTL
Table 5: SPDIF Output Module Register Summary
Remark: The clock frequency emitted by the DDs output can be found in
The Clock
Offset
0x10 9010
0x10 9014
0x10 9018—9FF0
0x10 9FF4
0x10 9FFC
Acces
s
R
R
R
R
R
W
R/W
Module.
0
0
0
0
1
0
0
Value
Rev. 1 — 17 March 2006
Name
SPDO_BASE2
SPDO_SIZE
Reserved
SPDO_PWR_DWN
SPDO_MODULE_ID
Description
To ensure software backward compatibility unused or reserved bits
must be written as zeros and ignored upon read.
This flag gets set if DMA buffer 1 has been emptied by the SPDO
hardware. The flag can be cleared only by a software write to
ACK_BUF1.
This flag gets set if DMA buffer 2 has been emptied by the SPDO
hardware. The flag can be cleared only by a software write to
ACK_BUF2.
Bandwidth Error. This flag gets set if the internal buffers in SPDO
were emptied before new memory data was brought in. This flag
can be cleared only by a software write to ACK_HBE.
This flag gets set if both DMA buffers were emptied before a new full
buffer was assigned by software. The hardware has performed a
normal buffer switch over and is emitting old data. It can only be
cleared by software write to ACK_UDR.
This flag gets set if the hardware is currently emitting DMA buffer 1
data, and is negated when emitting DMA buffer 2 data.
1 =Software Reset. Immediately resets the SPDO block. This
should be used with extreme caution. Any ongoing transmission will
be interrupted, and receivers may be left in a strange state.
1 =Enables transmission as per the selected mode.
0 =Transmission Disabled. Stops any ongoing transmission after
completing any actions related to the current data descriptor word.
Description
Base address of buffer2
Size of the buffers
Powerdown
Module ID
…Continued
© Koninklijke Philips Electronics N.V. 2006. All rights reserved.
Chapter 17: SPDIF Output
PNX17xx Series
Chapter 5
17-9
Related parts for PNX1700EH/G,557
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
![SAA7113H/V2,557](/images/no-image3.png)
Part Number:
Description:
Manufacturer:
Trident Microsystems, Inc.
Datasheet:
![SAA7118E/V1/M5,557](/photos/31/32/313229/165pin_bga_tmb.jpg)
Part Number:
Description:
Manufacturer:
Trident Microsystems, Inc.
Datasheet:
![SAA7129AH/V1,557](/images/no-image3.png)
Part Number:
Description:
Manufacturer:
Trident Microsystems, Inc.
Datasheet:
![SAA7105H/V1,557](/images/no-image3.png)
Part Number:
Description:
Manufacturer:
Trident Microsystems, Inc.
Datasheet: