LE3100MICH S L9PU Intel, LE3100MICH S L9PU Datasheet - Page 88

no-image

LE3100MICH S L9PU

Manufacturer Part Number
LE3100MICH S L9PU
Description
Manufacturer
Intel
Datasheet

Specifications of LE3100MICH S L9PU

Family Name
Xeon Processor 3100
Device Core Size
64b
Instruction Set Architecture
RISC
Operating Supply Voltage (max)
1.3625V
Operating Supply Voltage (min)
0.85V
Mounting
Surface Mount
Pin Count
1284
Package Type
FCBGA3
Lead Free Status / RoHS Status
Compliant
5.3.2.3
5.3.2.4
Table 5-4.
86
PECI Fault Handling Requirements
PECI is largely a fault tolerant interface, including noise immunity and error checking
improvements over other comparable industry standard interfaces. The PECI client is
as reliable as the device that it is embedded in, and thus given operating conditions
that fall under the specification, the PECI will always respond to requests and the
protocol itself can be relied upon to detect any transmission failures. There are,
however, certain scenarios where the PECI is know to be unresponsive.
Prior to a power on RESET# and during RESET# assertion, PECI is not assured to
provide reliable thermal data. System designs should implement a default power-on
condition that ensures proper processor operation during the time frame when reliable
data is not available via PECI.
To protect platforms from potential operational or safety issues due to an abnormal
condition on PECI, the Host controller should take action to protect the system from
possible damage. It is recommended that the PECI host controller take appropriate
action to protect the client processor device if valid temperature readings have not
been obtained in response to three consecutive GetTemp()s or for a one second time
interval. The host controller may also implement an alert to software in the event of a
critical or continuous fault condition.
PECI GetTemp0() Error Code Support
The error codes supported for the processor GetTemp() command are listed in
Table
GetTemp0() Error Codes
0x8000
0x8002
Error Code
5-4:
General sensor error
Sensor is operational, but has detected a temperature below its operational range
(underflow)
§ §
Thermal Specifications and Design Considerations
Description
Datasheet

Related parts for LE3100MICH S L9PU