HB28K032MM3 Renesas Electronics America, HB28K032MM3 Datasheet - Page 35

no-image

HB28K032MM3

Manufacturer Part Number
HB28K032MM3
Description
Manufacturer
Renesas Electronics America
Type
MultiMedia Cardr
Datasheet

Specifications of HB28K032MM3

Density
32MByte
Operating Supply Voltage (typ)
3.3V
Operating Temperature (min)
-25C
Operating Temperature (max)
85C
Package Type
Not Required
Mounting
Surface Mount
Pin Count
7
Operating Temperature Classification
Commercial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Programmable
Yes
Lead Free Status / RoHS Status
Compliant
HB28K032/L064/J128/J256/J512MM3, HB28K032/L064/J128/J256RM3
Data Transfer Mode
When in Standby State, both CMD and DAT lines are in the push-pull mode. As long as the content of all
CSD registers is not known, the f
allows the host to get the Card Specific Data (CSD register), e.g. ECC type, block length, card storage
capacity, maximum clock rate etc.
The command SELECT_DESELECT_CARD (CMD7) is used to select one card and place it in the
Transfer State. If a previously selected card is in the Transfer State its connection with the host is released
and it will move back to the Stand-by State. Only one card can be, at any time, in the Transfer State. A
selected card is responding the CMD7, the deselected one does not respond to this command. When
CMD7 is sent including the reserved relative card address 0x0000, all cards transfer back to Stand-by State.
This command is used to identify new cards without resetting other already acquired cards. Cards to which
an RCA has already been assigned, do not respond to the identification command flow in this state. All the
data communication in the Data Transfer Mode is consequently a point-to point communication between
the host and the selected card (using addressed commands). All addressed commands are acknowledged
by a response on the CMD line. All read commands (data is sent from the card via data lines) can be
interrupted at any time, by a stop command. The data transfer will terminate and the card will stop or start
working on the next command. The DAT bus line signal level is high when no data is transmitted. A
transmitted data block consists of a start bit (LOW), followed by a continuous data stream. The data
stream contains the net payload data (and error correction bits if an off-card ECC is used). The data stream
Rev.0.02, Sep.15.2004, page 35 of 89
card-identification mode
data-transfer mode
no state transition
in data-transfer mode
CMD13
''operation
complete''
Disconnect state
Stand-by state
MultiMediaCard State Diagram (Data Transfer Mode)
CMD9, 10
CMD3
(stby)
(dis)
PP
clock rate is equal to the slow f
CMD28, 29, 38
CMD15
from all states in
data-transfer mode
CMD7
CMD7
CMD0
CMD7
CMD7
''operation
complete''
Programming state
CMD24, 25
(prg)
CMD12,
''operation
complete''
OD
Sending-data state
Transfer state
clock rate. SEND_CSD (CMD9)
(data)
(tran)
Receive-data state
CMD11, 17, 18, 30
(rcv)
CMD20, 24, 25, 26, 27, 42
CMD12 or
''transfer end''
CMD16, 23, 35, 36

Related parts for HB28K032MM3