USB2504A-JT Standard Microsystems (SMSC), USB2504A-JT Datasheet - Page 26

no-image

USB2504A-JT

Manufacturer Part Number
USB2504A-JT
Description
Manufacturer
Standard Microsystems (SMSC)
Datasheet

Specifications of USB2504A-JT

Operating Temperature (min)
0C
Operating Temperature Classification
Commercial
Operating Temperature (max)
70C
Package Type
TQFP
Rad Hardened
No
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
USB2504A-JT
Quantity:
4 000
Part Number:
USB2504A-JT
Manufacturer:
SMSC
Quantity:
648
Part Number:
USB2504A-JT
Manufacturer:
Microchip Technology
Quantity:
10 000
Part Number:
USB2504A-JT
Manufacturer:
SMSC
Quantity:
20 000
Revision 2.3 (08-27-07)
5.3.1.1
5.3.2
5.3.3
Field:
Field:
Bits:
Bits:
Start
Start
1
Byte Protocols
When using the Hub SMBus Interface for byte transfers, a write will always consist of the SMBus
Interface Slave Address byte, followed by the Internal Address Register byte, then the data byte.
The normal read protocol consists of a write to the HUB with the SMBus Interface Address byte,
followed by the Internal Address Register byte. Then restart the Serial Communication with a Read
consisting of the SMBus Interface Address byte, followed by the data byte read from the Hub. This
can be accomplished by using the Read Byte protocol.
Note: For the following SMBus tables:
Write Byte
The Write Byte protocol is used to write data to the registers. The data will only be written if the protocol
shown in
protocol.
Read Byte
The Read Byte protocol is used to read data from the registers. The data will only be read if the
protocol shown in
Byte protocol.
Invalid Protocol Response Behavior
Registers that are accessed with an invalid protocol are not updated. A register is only updated
following a valid protocol. The only valid protocols are Write Byte and Read Byte, which are described
above.
The Hub only responds to the hardware selected Slave Address.
Attempting to communicate with the Hub over SMBus with an invalid slave address or invalid protocol
results in no response, and the SMBus Slave Interface returns to the idle state.
The only valid registers that are accessible by the SMBus slave address are the registers defined in
the Registers Section. See
General Call Address Response
The Hub does not respond to a general call address of 0000_000b.
1
Denotes Master-to-Slave
Slave
Addr
Slave Addr
7
Table 5.2
Wr
7
1
Table 5.3
is performed correctly. Only one byte is transferred at a time for a Write Byte
Ack
1
Table 5.2 SMBus Write Byte Protocol
Table 5.3 SMBus Read Byte Protocol
Wr
Section 5.3.3
1
is performed correctly. Only one byte is transferred at a time for a Read
Reg.
Addr
8
Ack
DATASHEET
1
Ack
1
for the response to undefined registers.
Reg. Addr
26
Denotes Slave-to-Master
Start
1
8
Slave
Addr
7
Ack
1
Rd
Integrated USB 2.0 Compatible 4-Port Hub
1
Reg. Data
Ack
1
8
SMSC USB2504/USB2504A
Reg.
Data
8
Ack
Nack
1
1
Datasheet
Stop
Stop
1
1